Circadian Blood Pressure Variations Computed From 1.7 Million Measurements in an Acute Hospital Setting
Adam Mahdi1, Peter Watkinson2,3, Richard J McManus4
1Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK.
Background:
Knowledge of the circadian blood pressure (BP) variations in the acute hospital setting is very limited.
Methods:
This is a retrospective analysis of BP data for in-hospital patients stratified by age and sex. We used data collected with the help of a standardized electronic health record system between March 2014 and April 2018 on the adult general wards in 4 acute hospitals in Oxford, UK.
Results:
A total of 41,455 unique patient admissions with 1.7 million sets of vital-sign measurements have been included in the study. The typical 24-hour systolic BP profile (dipping pattern during sleep followed by a gradual increase during the day) was only seen in the younger age groups (up to 40-49 for men and 30-39 for women). For older age groups, there was a late nocturnal rise in systolic BP, the amplitude of which increased with age. The late nocturnal BP rise above the age of 50 was seen whether or not the patient was treated for or previously identified with hypertension.
Conclusion:
Hospitalized patients' circadian patterns of BP largely mirror those found in the community. High-quality hospital data may allow for the identification of patients at significant cardiovascular risk through either opportunistic screening or systematic screening.
Related Concept Videos
Measurement of Blood Pressure
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Hospitals-II
Nurses that work in...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in...