[Construction of swept source optical coherence tomography imaging system for root canal endoscopy and application in
1Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
Objective:
To construct swept source optical coherence tomography (SS-OCT) imaging system for root canal endoscopy, and to evaluate the accuracy of diagnosing artificial root fractures.
Methods:
An ultra-high-speed (40 kHz) swept laser source was developed based on the piezoelectric tuning filter and the Fourier domain mode locking (FDML) swept laser technology (patent number: 200620135940.2). Ultra-miniature gradient index lens technology (patent number: 201320241218.7) was used to create a thin endoscopic probe with a diameter of 0.86 mm for real-time image transmission. The SS-OCT light source had a wavelength of 1 310 nm and a bandwidth of 100 nm. The axial and transverse image resolutions were 15 μm and 25 μm, respectively. Artificial fractures were created on human mandibular premolars with single root and the premolar roots were prepared to 41 horizontal sections (1 mm thick). 27 root sections with fractures (width: 52-284 μm) and 14 the sections without fractures were observed under an optical stereomicroscope with a cold light source as the gold standard. The horizontal root sections were scanned by self-developed SS-OCT imaging system for root canal endoscopy with a central wavelength of 1 310 nm and bandwidth of 100 nm. The data were reconstructed with 30 μm thick slices at an interval of 30 μm. Two observers, a radiologist and an endodontist, were trained and independently evaluated all the reconstructed images blindly. The diagnostic performance of SS-OCT imaging system was calculated, and statistical analysis was performed.
Results:
SS-OCT root canal endoscopic imaging system composed of high-speed swept laser source, fiber coupler, endoscopic probe, reference arm and differential detector. Root sections could be scanned by SS-OCT and imaged in realtime at a depth of 1 to 2 mm. The kappa value for interobserver agreement was 0.792, and the intraobserver agreement was 1.000 and 0.709 for two observers respectively. All of 27 fractured root sections and 12 of 14 root sections without fractures were accurately diagnosed while 2 unfractured root sections were misdiagnosed. The sensitivity was 1.000 and the specificity was 0.857 for diagnosis of artificial root fractures by SS-OCT. The positive predictive value (PPV), negative predictive value (NPV) and the overall accuracy rate were 0.931, 1.000 and 0.951 respectively.
Conclusion:
The swept source optical coherence tomography imaging system for root canal endoscopy is a promising imaging method for observing root fractures..
Related Concept Videos
Construction of Root Locus
For positive gain values, the root locus exists on the real axis to the left of an odd number of finite open-loop poles or zeros. The root locus starts at the open-loop poles and traces the paths of the closed-loop poles as the gain...
Primary and Secondary Growth in Roots and Shoots
Root Mean Square
For example, consider the velocity of gas molecules in a container. The gas molecules are moving in different directions, which might impart positive and negative...
Root-Locus Method
This system can be represented by a block...
Properties of the Root Locus
To determine if a point lies on the root locus, the criterion involves the sum of angles contributed by all poles and zeros to that point. Specifically, this sum must be an odd multiple of 180 degrees. The gain at any point on...
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...