Related Experiment Video
Updated: Jan 20, 2026

Author Spotlight: Innovative Technique for Coronary Angiography in Marginal Donors
Published on: July 12, 2024
CT Perfusion Versus Coronary CT Angiography in Patients With Suspected In-Stent Restenosis or CAD Progression
Daniele Andreini1, Saima Mushtaq2, Gianluca Pontone2
1Centro Cardiologico Monzino, IRCCS, Milan, Italy; Department of Clinical Sciences and Community Health, Cardiovascular Section, University of Milan, Milan, Italy.
Objectives:
The goal of this study was to assess the diagnostic performance of coronary computed tomography angiography (CTA) alone, adenosine-stress myocardial perfusion assessed by computed tomography (CTP) alone, and coronary CTA + CTP by using a 16-cm Z-axis coverage scanner versus invasive coronary angiography (ICA) and fractional flow reserve (FFR) as the clinical standard.
Background:
Diagnostic performance of coronary CTA for in-stent restenosis detection is still challenging. Recently, CTP showed additional diagnostic power over coronary CTA in patients with suspected coronary artery disease. However, few data are available on CTP performance in patients with previous stent implantation.
Methods:
Consecutive stable patients with previous coronary stenting referred for ICA were enrolled. All patients underwent stress myocardial CTP and rest CTP + coronary CTA. Invasive FFR was performed during ICA when clinically indicated. The diagnostic rate and diagnostic accuracy of coronary CTA, CTP, and coronary CTA + CTP were evaluated in stent-, territory-, and patient-based analyses.
Results:
In the 150 enrolled patients (132 men; mean age 65.1 ± 9.1 years), the CTP diagnostic rate was significantly higher than that of coronary CTA in all analyses (territory based [96.7% vs. 91.1%; p < 0.0001] and patient based [96% vs. 68%; p < 0.0001]). When ICA was used as gold standard, CTP diagnostic accuracy was significantly higher than that of coronary CTA in all analyses (territory based [92.1% vs. 85.5%, p < 0.03] and patient based [86.7% vs. 76.7%, p < 0.03]). The concordant coronary CTA + CTP assessment exhibited the highest diagnostic accuracy values versus ICA (95.8% in the territory-based analysis). The diagnostic accuracy of CTP was significantly higher than that of coronary CTA (75% vs. 30.5%; p < 0.001). The radiation exposure of coronary CTA + CTP was 4.15 ± 1.5 mSv.
Conclusions:
In patients with coronary stents, CTP significantly improved the diagnostic rate and accuracy of coronary CTA alone compared with both ICA and invasive FFR as gold standard.
More Related Videos
04:30A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Tumor Progression
Colon cancer is one of the best-documented examples of tumor progression. Early mutation in the APC gene in colon cells causes a small growth on the colon wall called a polyp. With time, this polyp grows into a benign, pre-cancerous tumor. Further...