Simultaneous detection of five flavoring agents in chewing gum by ultrasound-microwave synergistic extraction coupled with gas chromatography
Related Experiment Video
Updated: Jan 20, 2026

Arabidopsis thaliana Polar Glycerolipid Profiling by Thin Layer Chromatography TLC Coupled with Gas-Liquid Chromatography GLC
Published on: March 18, 2011
Junde Li1, Xiaojuan Liu1, Xin Liang1
1College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, 700 Changcheng Road, Qingdao, Shandong, 266109, China.
Abstract:
So far, the identification and determination of flavor additives in food has gained extensive attention in the area of food safety. However, it remains a big challenge for simultaneous detection of diverse flavor agents. In this work, a novel gas chromatography method coupled with ultrasound-microwave synergistic extraction was developed for simultaneous detection of five flavor compounds, including butyl butyrate, menthol, methyl salicylate, eugenol and vanilline. In this strategy, ultrasound-microwave synergistic extraction was used to extract the five flavoring agents from chewing gum. The effects of extractants, solid-liquid ratio, extraction time and microwave power on extraction yield were researched by using orthogonal test. After the optimization of programme temperature and splitless injection, the five flavoring agents were well separated and simultaneously detected with wide linear ranges, low limits of detection, high accuracy and good repeatability. Therefore, this proposed method would hold great promise for assay application on the food safety.
More Related Videos
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....