Related Experiment Video
Updated: Jan 20, 2026

Use of Rabbit Eyes in Pharmacokinetic Studies of Intraocular Drugs
Published on: July 23, 2016
Intravitreal Pharmacokinetics in Mice: SPECT/CT Imaging and Scaling to Rabbits and Humans
Mechthild Schmitt1, Eero Hippeläinen2,3, Manuela Raviña1
1Drug Research Program, Division of Pharmaceutical Biosciences, Faculty of Pharmacy , University of Helsinki , Helsinki , Finland.
Abstract:
Preclinical in vivo tests of retinal drug responses are carried out in mice and rats, often after intravitreal injections. However, quantitative pharmacokinetics in the mouse eye is poorly understood. Ocular pharmacokinetics studies are usually done in rabbits. We investigated elimination of three compounds ([99mTc]Tc-pentetate, [111In]In-pentetreotide, [99mTc]Tc-human serum albumin with molecular weights of 510.2 Da, 1506.4 Da, and 66.5 kDa, respectively) from mouse vitreous using imaging with single photon emission computed tomography/computed tomography (SPECT/CT). Increasing molecular weight decreased elimination of the compounds from the mouse eyes. Half-lives of [99mTc]Tc-pentetate, [111In]In-pentetreotide, and [99mTc]Tc-human serum albumin in the mouse eyes were 1.8 ± 0.5 h, 4.3 ± 1.7 h, and 30.0 ± 9.0 h, respectively. These values are 3-12-fold shorter than half-lives of similar compounds in the rabbit vitreous. Dose scaling factors were calculated for mouse-to-rabbit and mouse-to-man translation. They were 27-90 and 38-126, respectively, for intravitreal injections in rabbit and man. We show ocular pharmacokinetic parameters for mice and interspecies scaling factors that may augment ocular drug discovery and development.
More Related Videos
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
pH Scale
Pharmacokinetics: Overview
Pharmacokinetic Models: Overview
There are three primary types of models: empirical, compartment, and physiological. Empirical models, with minimal...