Related Experiment Video
Updated: Jan 20, 2026

Monocular Visual Deprivation and Ocular Dominance Plasticity Measurement in the Mouse Primary Visual Cortex
Published on: February 8, 2020
Real-Time Photometric Calibrated Monocular Direct Visual SLAM
Peixin Liu1, Xianfeng Yuan2, Chengjin Zhang1
1School of Mechanical Electrical and Information Engineering, Shandong University, Weihai 264209, China.
Abstract:
To solve the illumination sensitivity problems of mobile ground equipment, an enhanced visual SLAM algorithm based on the sparse direct method was proposed in this paper. Firstly, the vignette and response functions of the input sequences were optimized based on the photometric formation of the camera. Secondly, the Shi-Tomasi corners of the input sequence were tracked, and optimization equations were established using the pixel tracking of sparse direct visual odometry (VO). Thirdly, the Levenberg-Marquardt (L-M) method was applied to solve the joint optimization equation, and the photometric calibration parameters in the VO were updated to realize the real-time dynamic compensation of the exposure of the input sequences, which reduced the effects of the light variations on SLAM's (simultaneous localization and mapping) accuracy and robustness. Finally, a Shi-Tomasi corner filtered strategy was designed to reduce the computational complexity of the proposed algorithm, and the loop closure detection was realized based on the oriented FAST and rotated BRIEF (ORB) features. The proposed algorithm was tested using TUM, KITTI, EuRoC, and an actual environment, and the experimental results show that the positioning and mapping performance of the proposed algorithm is promising.
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
Calibration Curves: Correlation Coefficient
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...

