Related Experiment Video
Updated: Jan 20, 2026

Tissue-Engineered Graft for Circumferential Esophageal Reconstruction in Rats
Published on: February 10, 2020
Effects of Right Atrioventricular Expanded Polytetrafluoroethylene Path Graft Reconstruction on Arrhythmogenicity and
Takuma Aoki1, Makoto Doiguchi1
1From the Laboratory of Surgery 1, Department of Veterinary Medicine, School of Veterinary Medicine, Azabu University, Tokyo, Japan.
Abstract:
Right atrioventricular pericardial autografts, including the coronary groove, may cause myocardial ischemia. Our aim was to explore the effects of this procedure using an expanded polytetrafluoroethylene (ePTFE) patch on arrhythmogenicity and right ventricular function. Four healthy beagles and one client-owned golden retriever with recurrent cardiac tamponade as a result of hemangiosarcoma were included. The four healthy dogs underwent right atrioventricular ePTFE patch graft reconstruction after complete resection of the right auricle. Right ventricular function and arrhythmia were evaluated using tricuspid annular plane systolic excursion and tissue Doppler imaging on echocardiography and Holter electrocardiography, respectively, before and after surgery. The golden retriever underwent right atrioventricular ePTFE patch graft reconstruction followed by resection of the cardiac mass. None of the echocardiographic values, not involving systolic function, changed after surgery in the four healthy dogs. Transient arrhythmias tended to increase 1 day after surgery. The dog with recurrent cardiac tamponade exhibited more severe arrhythmia and required transient antiarrhythmic treatment for 3 days and survived the cardiac tamponade for 434 days after surgery. We showed that an ePTFE patch can serve as a suitable alternative material for right atrioventricular patch graft reconstruction, although transient arrhythmias may occur following surgery.
Related Concept Videos
Mean free path and Mean free time
Path Between Thermodynamics States
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion
Reconstruction of Signal using Interpolation
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...

