Related Experiment Video
Updated: Jan 20, 2026

Insect-controlled Robot: A Mobile Robot Platform to Evaluate the Odor-tracking Capability of an Insect
Published on: December 19, 2016
Simultaneous Calibration of Odometry and Head-Eye Parameters for Mobile Robots with a Pan-Tilt Camera
Nachaya Chindakham1, Young-Yong Kim2, Alongkorn Pirayawaraporn1
1Department of Control and Instrumentation Engineering; Kwangwoon University, Kwangwoon-ro 1-gil 60, Nowon-gu, Seoul 01890, Korea.
Abstract:
In the field of robot navigation, the odometric parameters, such as wheel radii and wheelbase length, and the relative pose of the optical sensing camera with respect to the robot are very important criteria for accurate operation. Hence, these parameters are necessary to be estimated for more precise operation. However, the odometric and head-eye parameters are typically estimated separately, which is an inconvenience and requires longer calibration time. Even though several researchers have proposed simultaneous calibration methods that obtain both odometric and head-eye parameters simultaneously to reduce the calibration time, they are only applicable to a mobile robot with a fixed camera mounted, not for mobile robots equipped with a pan-tilt motorized camera systems, which is a very common configuration and widely used for wide view. Previous approaches could not provide the z-axis translation parameter between head-eye coordinate systems on mobile robots equipped with a pan-tilt camera. In this paper, we present a full simultaneous mobile robot calibration of head-eye and odometric parameters, which is appropriate for a mobile robot equipped with a camera mounted on the pan-tilt motorized device. After a set of visual features obtained from a chessboard or natural scene and the odometry measurements are synchronized and received, both odometric and head-eye parameters are iteratively adjusted until convergence prior to using a nonlinear optimization method for more accuracy.
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
Calibration Curves: Correlation Coefficient
Wave Parameters
Muscles that Move the Head
The bilateral sternocleidomastoid, or SCM, and the suprahyoid and infrahyoid muscles are significant head flexors. The SCM muscles originate at the sternum and clavicle and attach to the mastoid process of the temporal bone. The SCM contracts bilaterally to bend the head forward, whereas...

