Related Experiment Video
Updated: Jan 20, 2026

A Decellularization Methodology for the Production of a Natural Acellular Intestinal Matrix
Published on: October 7, 2013
Comparative Study of Meshed and Nonmeshed Acellular Dermal Matrix in Immediate Breast Reconstruction
Adi Maisel Lotan1, Dafna Ben Yehuda1, Tanir M Allweis1
1From the Shaare Zedek Medical Center; The Hebrew University of Jerusalem; Assuta Medical Center; and Kaplan Medical Center.
Background:
Acellular dermal matrices are commonly used to support implant-based breast reconstruction. Meshing may enhance integration, reduce drain time and seroma, and decrease surgical costs.
Methods:
This was a retrospective, single-center analysis of 83 adult women (115 breasts) undergoing one-stage (84.3 percent) or two-stage (15.7 percent) immediate breast reconstruction with bovine-derived acellular dermal matrix (SurgiMend) meshed at a 2:1 ratio. Outcomes were compared with previously published data from a control group of 111 patients (147 breasts) undergoing the same procedure with nonmeshed (fenestrated) acellular dermal matrix.
Results:
The mean age of patients receiving meshed acellular dermal matrix was 48.3 years and the mean body mass index was 23.6 kg/m. There were no significant differences in baseline characteristics versus controls, other than chemotherapy history (received by fewer patients in the meshed acellular dermal matrix group). Mean follow-up was 23.6 months. Overall rates of minor and major complications in the meshed acellular dermal matrix group were 16.5 percent and 13.0 percent, respectively-similar to controls (25.2 percent and 12.9 percent). However, with meshed acellular dermal matrix, there were significantly fewer major seromas (0 percent versus 8.2 percent; OR, ∞; 95 percent CI, 1.927 to ∞), fewer total hematomas (0 percent versus 4.8 percent; OR, ∞; 95 percent CI, 1.022 to ∞), and fewer total infections (10.4 percent versus 23.8 percent; OR, 2.682; 95 percent CI, 1.259 to 5.802) compared with controls. Time to drain removal was reduced. Rates of capsular contracture (5.2 percent versus 2.7 percent) and explantation (5.2 percent versus 2.7 percent) were similar in the meshed acellular dermal matrix and control groups.
Conclusion:
Acellular dermal matrix meshing reduces rates of postoperative seroma, hematoma, and infection and decreases drain removal time compared with nonmeshed acellular dermal matrix.
Clinical Question/Level Of Evidence:
Therapeutic, III.
More Related Videos
13:35Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
11:02The Three-Dimensional Human Skin Reconstruct Model: a Tool to Study Normal Skin and Melanoma Progression
Published on: August 3, 2011
Related Concept Videos
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
The Extracellular Matrix
The Extracellular Matrix
In order to maintain tissue organization, many animal cells are surrounded by structural molecules that make up the extracellular matrix (ECM). Together, the molecules in the ECM maintain the structural integrity of tissue as well as the remarkable specific properties of certain tissues.
Composition of the Extracellular Matrix
The extracellular matrix (ECM) is commonly composed of ground substance, a gel-like fluid, fibrous components, and many structurally and functionally diverse...
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...