Abstract:
This paper compares the results of standard chemical analytical processes and electrochemical impedance spectroscopy (EIS) in the characterization of different beverages, namely ground coffee, soluble coffee, coffee substitutes, barley, cow milk, vegetable drinks, tea, plant infusions and plant mixtures. For the two approaches, the similarities between the experimental data are assessed by means of the Euclidean and Canberra distances. The resulting information is processed by means of the multidimensional scaling (MDS) clustering and visualization algorithm. The results of the chemical analytical processes and EIS reveal identical clusters for the two adopted distances. Furthermore, the robustness of the experimental and computational scheme are assessed by means of the Procrustes technique. The results confirm the effectiveness of combining the EIS and MDS.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Impedance Combination
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...