Related Experiment Video
Updated: Jan 20, 2026

Analysis of HBV-Specific CD4 T-cell Responses and Identification of HLA-DR-Restricted CD4 T-Cell Epitopes Based on a Peptide Matrix
Published on: October 20, 2021
External Quality Assessment on CD4+ T-Cell Count Using in-House Proficiency Testing Panels for CD4 Count Laboratories
Natnael Kidanu Yibalih1, Dawit Wolday2, Samuel Kinde3
1School of Medicine, Aksum University, College of Health Science and Comprehensive Specialized Hospital, Aksum, Ethiopia.
Background:
CD4+ T-cell count External Quality Assessment program is important for the evaluation of performance of CD4 count laboratories. The aim of this study was to assess the quality of CD4count laboratory performance using in-house Proficiency testing panels that perform routine CD4 counts in Addis Ababa, Ethiopia, 2013/14.
Methods:
Participating laboratories were 20, 23 and 25 in trials 1, 2 and 3, respectively. In-house prepared fresh whole blood samples both with "normal" and "low" CD4 values were sent to participating laboratories. Percentage and absolute counts of CD4+ T-lymphocytes were done using their routine procedures. Data were analyzed for each trial including trimmed mean, standard deviation (SD), percent coefficient of variation (%CV), residual, and standard deviation index (SDI) values for both absolute counts and percentages of CD4+ lymphocytes (%CD4).
Results:
Most participating laboratories produced results that were within 2SD of the mean. Average inter-laboratory precision (trimmed %CV) was 10.87% and 5.14% for CD4 absolute counts and %CD4, respectively. For normal material, the trimmed mean %CV was 9.59% and3.23% for CD4 absolute counts and %CD4, respectively. For low material, the trimmed mean % CV was 12.15% and 7.05% for CD4 absolute counts and %CD4 respectively. BDFACSCount™ users showed the best accuracy and precision as evidenced by longitudinal analysis.
Conclusion:
This study was found to help facilities in early identifying their gaps with regard to their CD4 count performance and in avoiding the challenges encountered during participation in external EQA providers like the high cost, transportation problem, feedback delay and CD4laboratory coverage.
Related Concept Videos
Testing Water Quality
Wood Panel Products
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...
External and Internal Respiration
Internal and External Forces
External Anatomy of the Kidney
The kidneys are located in the retroperitoneal space on either side of the vertebral column, protected posteriorly by the 11th and 12th ribs. The right kidney sits slightly lower than the left owing to the presence of the liver...

