Related Experiment Video
Updated: Jan 20, 2026

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Disparities between sonoluminescence, sonochemiluminescence and dosimetry with frequency variation under flow
Richard James Wood1, Judy Lee1, Madeleine J Bussemaker1
1Department of Chemical and Process Engineering, University of Surrey, Guildford, Surrey GU2 7XH, United Kingdom.
Abstract:
The effects of ultrasound (frequency and pressure amplitude) and external parameters (fluid flow rate and surface stabilisation) on active sonoluminescence (SL) and sonochemical (SC) bubbles were investigated using common characterisation techniques. The SL from water, sonochemiluminescence (SCL) from luminol solutions and iodide dosimetry were studied at flow rates of 0, 24, 228 and 626 mL/min at 44, 300 and 1000 kHz with and without surface stabilisation. An increase in flow, in general, decreased SL, SCL and dosimetry caused by a reduction in collapse intensity. However, all flow rates were also able to increase SL intensity and the highest flow rate (626 mL/min) could also increase SCL and dosimetry. For SL, augmentation with flow was attributed to a reduction in coalescence bubbles which cause growth to inactive size (44 kHz) and enhancement of the standing wave at the surface of solution (300 and 1000 kHz). Where agitation at the solution surface (44 kHz) caused aeration (without stabilisation), flow may have circulated additional cavitation nuclei, increasing SL. Increases in SCL intensity and dosimetry yields were attributed to increased bubble fragmentation which was more influential for the latter process. Disparities between SCL and dosimetry are discussed in terms of gas concentration and reaction energy requirements influenced by the transient nature of the bubbles. SL and SCL had complimentary behaviour when they were located in the same regions i.e. a reduction in SL resulted in an increase in SCL as bubbles moved from stable to transient in nature. The same was not observed when SL and SCL bubbles were located in different regions. The active region for SL/SCL could differ or overlap, depending on the standing to travelling wave proportions at each frequency effecting active regions. In some cases, increased standing wave proportions throughout the reactor (with surface stabilisation) did not facilitate an increase in SL intensity, as was expected. Here, the travelling wave without stabilisation enabled a stronger area of activity toward the surface with a localised standing wave.
More Related Videos
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Variation: Normal Distribution, Range, and Standard Deviation
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...