Handheld 3D scanning as a minimally invasive measuring technique for neonatal anthropometry
Edward T Andrews1, James J Ashton2, Freya Pearson1
1Department of Neonatal Medicine, Princess Anne Hospital, University Hospital Southampton NHS Foundation Trust, UK.
Background:
Measurement of length and head circumference (HC) in addition to weight is vital in assessing the nutritional status of preterm infants. Current anthropometry represents an interruption to preterm infants, and may not be possible in unstable infants. Handheld 3D scanning has the potential to perform bedside anthropometry (length and HC) in a less invasive manner. We aimed to evaluate the feasibility and performance of 3D scanning as a 'non-touch' measuring technique for routine anthropometry.
Methods:
Preterm infants born before 30 weeks gestation were recruited from a single neonatal unit. HC and length were measured both manually and by a handheld 3D scanner at recruitment and weekly until discharge. The two methods were compared using the Bland-Altman method and linear regression.
Results:
Seventeen infants had manual and 3D-scan measurements (67 HC, 87 length). The mean difference (95%CI) between manual and 3D-scan measures, as a percentage of the manual value, was 2.87% (2.27-3.47%) for HC and 3.10% (2.65-3.54%) for length. Correlation between manual and 3D measures was high; HC r = 0.957 and length 0.963. Bland-Altman plots showed reasonable agreement between the two methods, and there was a high correlation between scanner and manual measurements.
Conclusions:
These data show a high correlation between measurements gathered from 3D scan images and standard anthropometry. However, 3D measures are not yet precise enough for routine clinical use. Refinement of technique/technology may translate into practical monitoring the growth of preterm infants with minimal handling and without interruption to developmental care.
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Leaky Scanning
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...