Related Experiment Video
Updated: Jul 25, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Reject analysis in digital radiography: A local study on radiographers and students' attitude in Iran
Sajjad Rastegar1,2, Jalal Beigi1,2, Ehsan Saeidi1,2
1Student Research Committee, Paramedical Faculty, Rafsanjan University of Medical Sciences, Rafsanjan, Iran.
Abstract:
Reject analysis is as a quality indicator and critical tool for dose and image quality optimization in radiology departments. By reducing image rejection rate (RR), radiation dose to patients can be reduced effectively, yielding increased total cost-effectiveness. The aims of this study were to assess the rate of image rejection at 2 direct digital radiography (DR) departments to find the sources of rejection and to observe how radiology students and radiographers deal with image rejection. Two radiology departments were surveyed during a 3-month period for all imaging procedures. Type of examination, numbers, and reasons for digital image rejection were obtained by systems and questionnaire. A predefined questionnaire, including 13 causes for rejection, was filled by radiographers and students. Out of the 14 022 acquired images, 1116 were rejected, yielding an overall RR of 8%. Highest RRs were found for examination of cervical spine and lumbosacral. Positioning errors and improper patient preparation were the main reasons for digital image rejection. The image RR was small, but there is a need for optimizing radiographic practice, and enhancing radiographer's knowledge may enhance the performance.
Related Concept Videos
X-ray Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...