Related Experiment Video
Updated: Jan 20, 2026

Author Spotlight: Advancements and Challenges in Hepatitis B Virus Detection
Published on: December 15, 2023
Sequence-encoded quantitative invader assay enables highly sensitive hepatitis B virus DNA quantification in a single
Nan Sheng1, Bingjie Zou2, Huan Tong2
1School of Life Science and Technology, China Pharmaceutical University, Nanjing 210009, China. ghzhou@nju.edu.cn.
Abstract:
Accurately quantifying hepatitis B virus DNA (HBV-DNA) in serum is important in dynamic monitoring and prognosis evaluation for patients with hepatitis B. Routine assays based on real-time polymerase chain reaction (qPCR) for HBV-DNA quantification usually require laborious calibration curves and may bring bias from the biological samples. To enable absolute quantification of HBV-DNA in a single tube, we described a modification of the conventional Q-Invader assay by separately encoding targeted DNA and artificially designed internal quantitative-standard DNA (QS-DNA) at the flaps of the corresponding downstream probes. Quantification of targeted HBV-DNA was readily achieved by the difference in the quantification cycle value (Ct) between itself and QS-DNA. Furthermore, spiked-in QS-DNA before DNA extraction allowed errors caused by DNA extraction to be corrected. Two different gene regions covering eight genotypes were encoded with the same flap to avoid false-negative results. The method demonstrates a high sensitivity, which enables accurate detection of as low as 2 copies of the HBV-DNA plasmid or 20 IU mL-1 HBV-DNA in serum in a single tube. Successful quantification of 50 clinical samples indicates that our method is cost-effective, labor-saving and reproducible, and promising for the ultra-sensitive quantification analysis of many types of pathogens other than HBV.
Related Concept Videos
04:11Real-Time Polymerase Chain Reaction-Based Detection and Quantification of Hepatitis B Virus DNA
Calibration Curves
Calibration curves are used to understand the instrumental response to an analyte and predict the concentration in an unknown sample. Generally, a set of standard samples are made at various concentrations with a range than includes the unknown of interest and the instrumental response at each concentration is recorded. For more accuracy and to understand the error, the response at each concentration can be repeated so an error...
08:34Highly Sensitive Assay for Measurement of Arenavirus-cell Attachment
08:54Development and Testing of Species-specific Quantitative PCR Assays for Environmental DNA Applications
13:42Quantitation of Rabies Virus in Various Bovine Brain Structures
13:04A Protocol for Analyzing Hepatitis C Virus Replication
