Background And Objectives:
Very recently, Fresenius Kabi, improved the software (autoMNC lymphocytes, SW 04.03.08) for mononuclear cells (MNCs) collection with the aim to ameliorate the quality of harvest, employing the automated autoMNC lymphocytes software SW 04.03.09. Herein, we report the results of an observational study evaluating the feasibility of MNCs collection in patients undergoing extracorporeal photopheresis (ECP) at our centre, using the new COM.TEC software 04.03.08c for MNC collection, afterwards integrated in the software 04.03.09, available on the market since November 2018.
Materials And Methods:
Thirty adult patients (21 males and 9 females) with GvHD, Chronic Lung Allograft Dysfunction or renal rejection, were consecutively enrolled to undergo 1 ECP procedure by the offline technique, according to our internal protocol, processing 1·5 blood volumes. Feasibility of collection was defined as: Hct in collection bag ≤5%, MNCs purity (percentage of MNCs/bag) ≥80%, MNCs collection efficiency (CE2) ≥60%, patient's platelet depletion ≤50%.
Results:
Thirty ECP procedures were evaluated. Feasibility (defined by the four parameters previously described) of MNCs collection was observed in 1 out of the 30 harvests analysed. Median Hct in the product was 3·45% (IQR: 2·6-5·0), and median MNCs purity was 97·2% (IQR 89·1-98·6). Median CE2 for MNCs was 21·4% (IQR: 11·9-41·2), and median patient's platelet depletion was 36·2% (IQR 21·9-51·4).
Conclusion:
The autoMNC lymphocytes software SW 04.03.08c for MNCs collection in ECP setting demonstrated to collect a good quality product in terms of purity and RBC contamination even if the collection efficiency and platelet contamination must be improved.
Related Concept Videos
08:47Automated Analysis of C. elegans Swim Behavior Using CeleST Software
07:21Automated Interactive Video Playback for Studies of Animal Communication
07:21Automated, High-Throughput Detection of Bacterial Adherence to Host Cells
06:41Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
12:13Generation of Induced Neural Stem Cells from Peripheral Mononuclear Cells and Differentiation Toward Dopaminergic Neuron Precursors for Transplantation Studies
09:31Automated Quantification of Hematopoietic Cell – Stromal Cell Interactions in Histological Images of Undecalcified Bone