Related Experiment Video
Updated: Jan 20, 2026

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Quantitative Three-Dimensional Echocardiographic Correlates of Optimal Mitral Regurgitation Reduction during
Didem Oguz1, Mackram F Eleid1, Sumandeep Dhesi1
1Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota.
Background:
Patient selection for transcatheter edge-to-edge mitral valve repair (TMVR) remains challenging because of heterogenous mitral valve pathology and highly variable anatomy. The aim of this study was to investigate whether quantitative three-dimensional (3D) transesophageal echocardiographic modeling parameters are associated with optimal mitral regurgitation (MR) reduction in patients undergoing TMVR.
Methods:
Fifty-nine patients underwent 3D transesophageal echocardiography during TMVR. Volumetric data sets were retrospectively analyzed using mitral valve quantitative 3D modeling software (Mitral Valve Navigator). Optimal MR reduction was defined as less than moderate residual MR. Logistic regression was used to correlate 3D transesophageal echocardiographic quantitative data to procedural success.
Results:
Thirty-five patients had primary MR, 24 had mixed or secondary MR, and all patients had grade ≥ 3/4 MR before the procedure. Optimal MR reduction was achieved in 40 of 59 patients (68%). Univariate correlates of optimal MR reduction in patients with primary MR were lower mitral leaflet tenting volume (P = .049) and lower tenting height (P = .025); tenting height < 3 mm and tenting volume < 0.7 mL were associated with increased likelihood of optimal MR reduction (92% vs 48% [P = .01] and 81% vs 47% [P = .03], respectively). In mixed or secondary MR, annular height ≥ 5.5 mm was associated with increased likelihood of optimal MR reduction (94% vs 38%; P = .03). During follow-up, redo TMVR or surgical mitral valve replacement occurred exclusively in patients with suboptimal anatomy defined by 3D transesophageal echocardiography (10% vs 0%, P = .045).
Conclusions:
Quantitative 3D echocardiographic data are associated with favorable response to TMVR and could help optimize patient selection.
Related Concept Videos
08:31A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
07:42An Image Guided Transapical Mitral Valve Leaflet Puncture Model of Controlled Volume Overload from Mitral Regurgitation in the Rat
09:13Optimized Protocol for the Extraction of Proteins from the Human Mitral Valve
08:12Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
07:41Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Mitral Regurgitation I: Introduction

