Related Experiment Video
Updated: Jan 20, 2026

Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens
Published on: September 12, 2016
A comparison of deltopectoral versus Judet approach for glenoid exposure
Rongguang Ao1, Zhen Jian1, Jianhua Zhou1
1Department of Orthopaedics, Shanghai Pudong Hospital, Shanghai Fudan University Pudong Medical Center, Shanghai, China.
Background:
Open reduction-internal fixation via an anterior or posterior approach is a widely used method for treating displaced glenoid fractures. This study aimed to identify the exposure range of the glenoid rim by these 2 approaches (deltopectoral and Judet approaches) and provide reference data for the choice of surgical approach.
Methods:
Twelve cadaveric shoulders were dissected. Both deltopectoral and Judet approaches were performed on each shoulder to mark the glenoid fracture. In addition, the shoulder was disarticulated to record the exposure range of the glenoid rim.
Results:
For the deltopectoral approach, the range of the exposed glenoid rim was from 5:50 to 11:30, which accounted for about 47.2% of the clock face. For the Judet approach, the range of the exposed glenoid rim was from 1:30 to 6:20, which accounted for about 40.3% of the clock face. Along the inferior glenoid, there was an area of partial overlap for the 2 approaches. The superior glenoid rim located from 11:30 to 1:30 was considered inaccessible, as it could not be exposed by the 2 approaches.
Conclusion:
Less than 50% of the glenoid rim can be exposed by the deltopectoral or Judet approach. With a single approach, it may be difficult to expose and fix some complex glenoid fractures. The superior part of the glenoid fracture is the non-access area via the deltopectoral or Judet approach.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
09:08Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits

