Related Experiment Video
Updated: Jan 20, 2026
Hydraulic Jumps in Radial Outflow of Water
Published on: April 30, 2023
Maximum velocity during loaded countermovement jumps obtained with an accelerometer, linear encoder and force
Amelia Ferro1, Pablo Floría2, Jorge Villacieros1
1Department of Sports, Faculty of Physical Activity and Sport Sciences, Universidad Politécnica de Madrid, Madrid, Spain.
Abstract:
The maximum velocity (Vmax) reached during countermovement jumps (CMJ) has been considered a performance indicator to evaluate vertical jump ability. The aim of this study was to compare Vmax during loaded CMJ (CMJloaded) using three different technologies to show a criterion for selecting the more appropriate depending on its use. Nine recreationally active men performed a CMJloaded test. Five jumps were made in each of 6 series with a 20- kg barbell + 0, + 5, + 10, + 15, + 20 and + 25 kg, with 2 seconds rest between the jumps and 5 minutes rest between the series to explore a wide range of speeds. Vmax was obtained from force platform, inertial device and linear encoder technologies. Bland-Altman plots and mean differences were used to compare devices. Reproducibility was tested using the intraclass correlation coefficient (ICC) for single measures and typical error (TE). All technologies showed high levels of reproducibility, ICC higher than 0.75 and TE lower than 10 %. There were non-significant differences in Vmax between each pair of technologies (linear encoder 2.11 ± 0.24 m·s-1, accelerometer 2.11 ± 0.26 m·s-1, force platform 2.12 ± 0.24 m·s-1) reporting a very low bias. However the limits of agreement between the different technologies evaluated were high (± 0.33 m·s-1). In conclusion, the accelerometer, linear encoder and force platform were suitably reliable to be used to measure Vmax during loaded vertical jumps but their values were not interchangeable.
Related Concept Videos
Hydraulic Jumps
When liquid flows along an open channel at high velocity, the flow can become unstable, and slight disturbances can cause the liquid upper surface to transition abruptly to a higher level (Fig. 1a). This sharp increase in the liquid level is called a hydraulic jump. The increase in the liquid level causes a reduction in the average flow velocity....
12:39Maximum Isometric Tetanic Force Measurement of the Tibialis Anterior Muscle in the Rat
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
11:30Measurement of Maximum Isometric Force Generated by Permeabilized Skeletal Muscle Fibers
Force and Acceleration
06:21Postural Organization of Gait Initiation for Biomechanical Analysis Using Force Platform Recordings

