Rapid and high-precision sizing of single particles using parallel suspended microchannel resonator arrays and

Max A Stockslager1, Selim Olcum2, Scott M Knudsen2

  • 1Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.

Abstract

Related Concept Videos

A Femtoliter Droplet Array for Massively Parallel Protein Synthesis from Single DNA Molecules10:45

A Femtoliter Droplet Array for Massively Parallel Protein Synthesis from Single DNA Molecules

The overall goal of the protocol is to prepare over one million ordered, uniform, stable, and biocompatible femtoliter droplets on a 1 cm2 planar substrate that can be used for cell-free protein...
10.8K
An Ultra-clean Multilayer Apparatus for Collecting Size Fractionated Marine Plankton and Suspended Particles09:01

An Ultra-clean Multilayer Apparatus for Collecting Size Fractionated Marine Plankton and Suspended Particles

Plankton and suspended particles play a major role in the biogeochemical cycles in the ocean. Here, we provide an ultra-clean, low stress method for the collection of various sizes of particles and plankton at sea with the capability of handling large volumes of...
9.3K
Precise Electrochemical Sizing of Individual Electro-Inactive Particles05:03

Precise Electrochemical Sizing of Individual Electro-Inactive Particles

As an analytical technique, nanoimpact electrochemistry, an increasingly important approach to counting and characterizing nanometer-scale, electro-inactive particles, suffers from poor precision due to the heterogeneous current distributions that arise from its use of ultramicroelectrodes. Outlined here is a generalized approach, termed "electrocatalytic interruption," that enhances precision in such...
1.7K
Parallel Resonance01:23

Parallel Resonance

The parallel RLC circuit is an arrangement where the resistor (R), inductor (L), and capacitor (C) are all connected to the same nodes and, as a result, share the same voltage across them. The parallel RLC circuit is analyzed in terms of admittance (Y), which reflects the ease with which current can flow. The admittance is given by:
529
A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice11:32

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice

This protocol describes a system architecture for performing automated small volume (0.15–1.5 ml) particle separations using a microfluidic device, and discusses methods to optimize acoustofluidic device performance and...
14.3K
Active Probe Atomic Force Microscopy with Quattro-Parallel Cantilever Arrays for High-Throughput Large-Scale Sample Inspection05:04

Active Probe Atomic Force Microscopy with Quattro-Parallel Cantilever Arrays for High-Throughput Large-Scale Sample Inspection

Large-scale sample inspection with nanoscale resolution has a wide range of applications, especially for nanofabricated semiconductor wafers. Atomic force microscopes can be a great tool for this purpose, but are limited by their imaging speed. This work utilizes parallel active cantilever arrays in AFMs to enable high-throughput and large-scale...