Contrast-induced nephropathy (CIN) has long been observed in both experimental and clinical studies. However, recent observational studies have questioned the prevalence and severity of CIN following intravenous contrast exposure. Initial studies of acute kidney injury following intravenous contrast were limited by the absence of control groups or contained control groups that did not adjust for additional acute kidney injury risk factors, including prevalent chronic kidney disease, as well as accepted prophylactic strategies. More contemporary use of propensity score-adjusted models have attempted to minimize the risk for selection bias, although bias cannot be completely eliminated without a prospective randomized trial. Based on existing data, we recommend the following CIN risk classification: patients with estimated glomerular filtration rates (eGFRs) ≥ 45mL/min/1.73m2 are at negligible risk for CIN, while patients with eGFRs<30mL/min/1.73m2 are at high risk for CIN. Patients with eGFRs between 30 and 44mL/min/1.73m2 are at an intermediate risk for CIN unless diabetes mellitus is present, which would further increase the risk. In all patients at any increased risk for CIN, the risk for CIN needs to be balanced by the risk of not performing an intravenous contrast-enhanced study.
Related Concept Videos
06:49Phase Contrast and Differential Interference Contrast (DIC) Microscopy
05:50Contrast Enhanced Vessel Imaging using MicroCT
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
07:50Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization
10:39Contrast Imaging in Mouse Embryos Using High-frequency Ultrasound
08:22Combined Intravital Microscopy and Contrast-enhanced Ultrasonography of the Mouse Hindlimb to Study Insulin-induced Vasodilation and Muscle Perfusion