Related Experiment Video
Updated: Jan 20, 2026
Intraosseous Needle Placement Using a Intraosseous Drill
Published on: April 30, 2023
A new method for reducing operation time and radiation exposure in the placement of Jamshidi needles: Technical note
Xu Li1, Xianzuo Zhang1, Chen Deng1
1Spine Center, Department of Orthopedics, Anhui Provincial Hospital, The First Affiliated Hospital of USTC, No. 17, Lujiang Road, Hefei 230001, China.
Abstract:
Percutaneous pedicle screws have been used in the treatment of thoracolumbar fractures for decades, and conventional fluoroscopy is commonly used to confirm the positions of the Jamshidi needles during the procedure. In this article, a modified method is reported for the placement of Jamshidi needles. The attending surgeons did not receive any radiation during the procedure and the fluoroscopy time for the patients was little. In our method, all six Jamshidi needles were placed on the pedicles and hammered 2 mm into each entry site. When the verification images were acquired, the medical personnel went behind a lead-lined wall. The positions of the needles were first reviewed and adjusted as needed based on the anterior-posterior (AP) image. Then, the C-arm was rotated and lateral images were obtained to further verify the needle placement. The rest of the screw placement procedure remained the same. The proposed technique was applied in 45 patients with thoracolumbar fractures. It took an average (range) of 5 (4-7) single-shot images to ensure all the needles were positioned at the ideal entry site and 12 (10-17) minutes to complete this step. No neurological symptoms were reported by the patients. Using the proposed technique, the radiation exposure for the surgeons is zero, and the patients are well-protected from excessive radiation exposure. This modified method of embedding all the Jamshidi needles at the entry sites before fluoroscopy is an improved technique compared with the conventional method.
Related Concept Videos
Intraosseous Needle Placement
For unstable patients requiring urgent administration of medications, fluids, or blood products, establishing vascular access quickly is essential. However, there are many factors that can complicate placement of a peripheral intravenous cannula (PIV), and it is extremely common for PIV attempts to fail. PIV placement may be technically challenging in...
03:20Studying Chronic Exposure of Mice to Ultraviolet B Radiation
07:54Experimental Methods of Dust Charging and Mobilization on Surfaces with Exposure to Ultraviolet Radiation or Plasmas
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
05:32Povidone Iodine Rectal Preparation at Time of Prostate Needle Biopsy is a Simple and Reproducible Means to Reduce Risk of Procedural Infection
Arterial Line Placement
When monitoring patients, it is important to obtain values that are accurate and reliable. Blood pressure monitoring is one of the essential vital signs, and for a majority of patients, measuring it utilizing non-invasive techniques provides accurate values. However, there are situations in which the blood pressure requires more exact, specific, and reliable measurements....