Related Experiment Video
Updated: Jan 20, 2026
Infrared Spectroscopy: Characterization of Functional Groups
Published on: April 30, 2023
Phase dual-slopes in frequency-domain near-infrared spectroscopy for enhanced sensitivity to brain tissue: First
Giles Blaney1, Angelo Sassaroli1, Thao Pham1
1Department of Biomedical Engineering, Tufts University, Medford, Massachusetts.
Abstract:
We present a first in vivo application of phase dual-slopes (DSϕ), measured with frequency-domain near-infrared spectroscopy on four healthy human subjects, to demonstrate their enhanced sensitivity to cerebral hemodynamics. During arterial blood pressure oscillations elicited at a frequency of 0.1 Hz, we compare three different ways to analyze either intensity (I) or phase (ϕ) data collected on the subject's forehead at multiple source-detector distances: Single-distance, single-slope and DS. Theoretical calculations based on diffusion theory show that the method with the deepest maximal sensitivity (at about 11 mm) is DSϕ. The in vivo results indicate a qualitative difference of phase data (especially DSϕ) and intensity data (especially single-distance intensity [SDI]), which we assign to stronger contributions from scalp hemodynamics to SDI and from cortical hemodynamics to DSϕ. Our findings suggest that scalp hemodynamic oscillations may be dominated by blood volume dynamics, whereas cortical hemodynamics may be dominated by blood flow velocity dynamics.
Related Concept Videos
Infrared Spectroscopy
This experiment will demonstrate the use of infrared (IR) spectroscopy (also known as vibrational spectroscopy) to elucidate the identity of an unknown compound by identifying the functional group(s) present. IR spectra will be obtained on an IR spectrometer using the attenuated total reflection (ATR) sampling technique with a neat sample of the...
04:36Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
06:42Conducting Hyperscanning Experiments with Functional Near-Infrared Spectroscopy
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Functional Near-Infrared Spectroscopy for Recording Brain Activity During Social Interactions

