Related Experiment Video
Updated: Jan 20, 2026

3D Modeling of the Lateral Ventricles and Histological Characterization of Periventricular Tissue in Humans and Mouse
Published on: May 19, 2015
Use of 3D Models in the Surgical Decision-Making Process in a Case of Double-Outlet Right Ventricle With Multiple
Andrew I U Shearn1, Michael Yeong2, Michael Richard3
1Bristol Medical School, University of Bristol, Bristol, United Kingdom.
Abstract:
3D printing has recently become an affordable means of producing bespoke models and parts. This has now been extended to models produced from medical imaging, such as computed tomography (CT). Here we report the production of a selection of 3D models to compliment the available imaging data for a 12-month-old child with double-outlet right ventricle and two ventricular septal defects. The models were produced to assist with case management and surgical planning. We used both stereolithography and polyjet techniques to produce white rigid and flexible color models, respectively. The models were discussed both at the joint multidisciplinary meeting and between surgeon and cardiologist. From the blood pool model the clinicians were able to determine that the position of the coronary arteries meant an arterial switch operation was unlikely to be feasible. The soft myocardium model allowed the clinicians to assess the VSD anatomy and relationship with the aorta. The models, therefore, were of benefit in the development of the surgical plan. It was felt that the clinical situation was stable enough that an immediate intervention was not required, but the timing of any intervention would be dictated by decreasing oxygen saturation. Subsequently, the oxygen saturation of the patient did decrease and the decision was made to intervene. A further model was created to demonstrate the tricuspid apparatus. An arterial switch was ultimately performed without the LeCompte maneuver, the muscular VSD enlarged and baffled into the neo aortic root and the perimembranous VSD closed. At 1 month follow up SO2 was 100%, there was no breathlessness and no echocardiogram changes.
Related Concept Videos
15:263D Modeling of the Lateral Ventricles and Histological Characterization of Periventricular Tissue in Humans and Mouse
09:15Creation of Patient-Specific Silicone Cardiac Models with Applications in Pre-surgical Plans and Hands-on Training
08:19A Pipeline to Characterize Structural Heart Defects in the Fetal Mouse
06:34Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
07:11Morphological and Functional Assessment of the Right Ventricle Using 3D Echocardiography
02:49A Swine Burn Model for Investigating the Healing Process in Multiple Depth Burn Wounds