Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Alignment of Visible-Light Optical Coherence Tomography Fibergrams with Confocal Images of the Same Mouse Retina07:02

Alignment of Visible-Light Optical Coherence Tomography Fibergrams with Confocal Images of the Same Mouse Retina

2.1K
The present protocol outlines the steps for aligning in vivo visible-light optical coherence tomography fibergraphy (vis-OCTF) images with ex vivo confocal images of the same mouse retina for the purpose of verifying the observed retinal ganglion cell axon bundle morphology in the in vivo images.
2.1K
Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)

8.9K
Here, we present a protocol to get a large field of view (FOV) three-dimensional (3D) fluorescence and OCT retinal image by using a novel imaging multimodal platform. We will introduce the system setup, the method of alignment, and the operational protocols. In vivo imaging will be demonstrated, and representative results will be provided.
8.9K
In Vivo Imaging of the Mouse Retina Using Optical Coherence Tomography04:08

In Vivo Imaging of the Mouse Retina Using Optical Coherence Tomography

719
Source: Jagodzinska, J., et. al.,  Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo. J. Vis. Exp. (2017)  In this video, we demonstrate the use of spectral-domain optical coherence tomography (SD-OCT) to image retinal layers and assess structural changes in a genetically modified mouse model with optic...
719
In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy06:19

In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy

11.2K
This protocol describes how high-resolution imaging techniques such as spectral domain optical coherence tomography and scanning laser ophthalmoscopy can be utilized in small rodents, using an ophthalmic imaging platform system, to obtain information on retinal thickness and microglial cell distribution,...
11.2K
Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography11:21

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography

11.9K
Photoacoustic ophthalmology (PAOM), an optical-absorption-based imaging modality, provides the complementary evaluation of the retina to the currently available ophthalmic imaging technologies. We report the using of PAOM integrated with spectral-domain optical coherence tomography (SD-OCT) for simultaneous multimodal retinal imaging in...
11.9K
Optical Coherence Tomography Imaging for Assessing Uveitis in a Mouse Model03:12

Optical Coherence Tomography Imaging for Assessing Uveitis in a Mouse Model

734
This video demonstrates an in vivo imaging technique for detecting and quantifying eye inflammation in a mouse model of post-infectious uveitis. The technique, known as optical coherence tomography (OCT), generates high-resolution cross-sectional images of the eye for assessing disease...
734

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Toward autonomous robotic-assisted and microrobotic surgery.

Science advances·2026
Same author

Vis-OCT Explorer: an open-source software for visible-light optical coherence tomography data processing.

Biomedical optics express·2026
Same author

The dynamics of nucleolus-centromeres interaction in living cells.

bioRxiv : the preprint server for biology·2026
Same author

Super-resolution functional photoacoustic microscopy via label-free cell tracking.

Light, science & applications·2026
Same author

PROX1 loss in adult mouse Schlemm's canal causes permanent ocular hypertension.

bioRxiv : the preprint server for biology·2025
Same author

Optical strategies for in vivo retinal ganglion cell imaging.

Med-X·2025
Same journal

<i>Neurophotonics</i> book club: "The Secret of Secrets" by Dan Brown - a thought-provoking twist on a famous neuroscience controversy.

Neurophotonics·2026
Same journal

Measurement of the absolute value of the optical birefringence of myelin in primate brain tissue.

Neurophotonics·2026
Same journal

Data-driven optimization of preschoolers' hemodynamic response in a VR setup: advancing analytic methods for children's fNIRS naturalistic data with the AICopt method.

Neurophotonics·2026
Same journal

Multimodal optical imaging combining voltage-sensitive dye ElectroFluor630 with genetically encoded calcium, glutamate, or voltage indicators.

Neurophotonics·2026
Same journal

Data-driven wavelet coherence approach to assess neurovascular coupling in neonatal hypoxic-ischemic encephalopathy.

Neurophotonics·2026
Same journal

Effect of sleep stage on patterns of fNIRS hemodynamic response to auditory paradigms in 1-month-old Gambian and UK infants.

Neurophotonics·2026
See all related articles

Related Experiment Video

Updated: Jan 20, 2026

Author Spotlight: Advancements in In Vivo and Ex Vivo Retinal Imaging for Improved Glaucoma Diagnosis and Treatment
07:02

Author Spotlight: Advancements in In Vivo and Ex Vivo Retinal Imaging for Improved Glaucoma Diagnosis and Treatment

Published on: June 30, 2023

2.1K

Speckle reduction in visible-light optical coherence tomography using scan modulation.

Ian Rubinoff1, Lisa Beckmann1, Yuanbo Wang2

  • 1Northwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States.

Neurophotonics
|September 5, 2019
PubMed
Summary
This summary is machine-generated.

This study introduces a new method to improve image clarity in visible-light optical coherence tomography by reducing speckle noise. By slightly moving the scanning beam during image collection, the researchers can combine multiple images to create a clearer, more detailed view of retinal structures. This technique works well for both human and animal eyes while keeping important details intact.

Keywords:
clinicimagingoptical coherence tomographyretinaspecklevisible lightretinal imagingimage quality enhancementB-scan modulationsignal processing

Frequently Asked Questions

More Related Videos

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT

Published on: August 4, 2018

8.9K
In Vivo Imaging of the Mouse Retina Using Optical Coherence Tomography
04:08

In Vivo Imaging of the Mouse Retina Using Optical Coherence Tomography

Published on: May 29, 2025

719

Related Experiment Videos

Last Updated: Jan 20, 2026

Author Spotlight: Advancements in In Vivo and Ex Vivo Retinal Imaging for Improved Glaucoma Diagnosis and Treatment
07:02

Author Spotlight: Advancements in In Vivo and Ex Vivo Retinal Imaging for Improved Glaucoma Diagnosis and Treatment

Published on: June 30, 2023

2.1K
Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT

Published on: August 4, 2018

8.9K
In Vivo Imaging of the Mouse Retina Using Optical Coherence Tomography
04:08

In Vivo Imaging of the Mouse Retina Using Optical Coherence Tomography

Published on: May 29, 2025

719

Area of Science:

  • Biomedical imaging within visible-light optical coherence tomography research
  • Ophthalmology and diagnostic imaging technologies

Background:

No prior work had resolved the persistent challenge of speckle noise degrading image quality in high-resolution optical imaging systems. This granular interference often obscures delicate biological structures, limiting the diagnostic utility of standard scanning protocols. Prior research has shown that traditional averaging techniques frequently result in blurred edges or reduced spatial resolution. That uncertainty drove the development of alternative strategies to improve signal clarity without sacrificing structural fidelity. It was already known that visible-light optical coherence tomography provides superior axial resolution compared to near-infrared counterparts. However, the inherent speckle patterns remain a significant hurdle for clinical interpretation and automated analysis. This gap motivated the investigation of scan modulation as a potential solution for noise suppression. Researchers sought to maintain high-fidelity imaging while simultaneously enhancing the contrast of fine anatomical features.

Purpose Of The Study:

The aim of this study is to present a novel technique for minimizing speckle noise in visible-light optical coherence tomography. Researchers sought to address the degradation of image quality caused by granular interference in high-resolution scans. The primary motivation was to develop a method that enhances contrast without losing fine structural details. This approach specifically targets the challenge of maintaining image fidelity during live retinal examinations. The team intended to create a robust protocol that remains effective even when subjects exhibit minor involuntary movements. By modulating the scanning beam, the authors aimed to acquire uncorrelated data sets from the same anatomical locations. This strategy was designed to facilitate effective averaging, thereby improving the overall signal-to-noise characteristics of the images. The study seeks to provide a practical solution for improving diagnostic clarity in both clinical and experimental ocular imaging.

Main Methods:

The review approach involved evaluating a novel technique designed to suppress noise in high-resolution ocular imaging. Investigators performed in-vivo retinal scans using both mice and human participants to validate the proposed methodology. The team implemented modulated raster and circular scanning patterns to capture diverse data points from identical anatomical sites. They compared these modulated results against standard unmodulated B-scan images to assess performance gains. Quantitative analysis focused on calculating the contrast-to-noise ratio and the equivalent number of looks for each image set. The researchers utilized an A-line rate of 25 kilohertz to maintain efficient data acquisition speeds. They averaged eight modulated A-lines to determine the optimal balance between noise suppression and structural preservation. This systematic comparison provided a rigorous assessment of the technique's effectiveness across different biological models.

Main Results:

Key findings from the literature indicate that the proposed modulation technique yields substantial improvements in image quality metrics. The researchers observed a maximum enhancement of 2.35 decibels in the contrast-to-noise ratio compared to standard imaging. Furthermore, the equivalent number of looks demonstrated an improvement of up to 3.1-fold using the specified averaging parameters. These results were achieved while maintaining the visibility of fine anatomical features within the retinal layers. The study confirmed that the method functions effectively in both murine and human retinal models. The data suggest that the orthogonal movement of the scanning beam successfully produces uncorrelated speckle patterns. This successful decorrelation allows for effective averaging without the blurring typically associated with standard image processing. The reported improvements remain consistent across the tested scanning configurations, confirming the utility of this approach.

Conclusions:

The authors propose that scan modulation effectively suppresses speckle noise while preserving critical structural details in retinal imaging. This synthesis suggests that orthogonal beam movement provides a reliable mechanism for generating uncorrelated data sets. The findings imply that averaging these distinct patterns significantly boosts image quality metrics like contrast-to-noise ratio. The researchers demonstrate that this approach remains robust even when subjects exhibit minor involuntary movements during the acquisition process. Their analysis indicates that the method is applicable across different species, including both mice and human subjects. The evidence supports the integration of modulated scanning patterns into existing diagnostic workflows to improve visual clarity. The authors conclude that achieving higher equivalent number of looks is possible without compromising the speed of data collection. This work provides a framework for future improvements in high-resolution ocular imaging technology.

The researchers propose that locally modulating B-scans orthogonally to the acquisition axis generates uncorrelated speckle patterns. Averaging these distinct patterns from identical anatomical regions reduces noise while maintaining structural integrity, resulting in improved image quality metrics.

The authors utilize modulated raster and circular scan patterns to acquire the necessary data. These specific scanning geometries allow for the collection of multiple, slightly varied views of the same tissue, which are then combined to enhance the final image.

The researchers state that orthogonal modulation is necessary to ensure the captured speckle patterns are uncorrelated. This lack of correlation between successive scans is the key requirement for effective averaging and subsequent noise suppression in the final output.

The authors use the contrast-to-noise ratio and the equivalent number of looks to quantify image quality. These metrics allow for a direct comparison between standard unmodulated images and the new speckle-reduced images obtained from the same locations.

The researchers report a maximum improvement of 2.35 decibels in the contrast-to-noise ratio. Additionally, they observed up to a 3.1-fold increase in the equivalent number of looks when using eight averaged A-lines at a 25-kilohertz rate.

The authors suggest that this technique is robust against sample motion, which is a common challenge in live imaging. They propose that this stability makes the method suitable for clinical applications where patient cooperation or movement might otherwise compromise image quality.