Related Experiment Video
Updated: Jan 20, 2026

Unilateral Lung Volume Analysis Using Micro-CT for Enhanced Assessment of Pulmonary Fibrosis in Preclinical Models
Published on: June 20, 2025
Computer-Aided Diagnosis of Pulmonary Fibrosis Using Deep Learning and CT Images
Andreas Christe1, Alan A Peters1, Dionysios Drakopoulos1
1From the Departments of Diagnostic, Interventional, and Pediatric Radiology.
Objectives:
The objective of this study is to assess the performance of a computer-aided diagnosis (CAD) system (INTACT system) for the automatic classification of high-resolution computed tomography images into 4 radiological diagnostic categories and to compare this with the performance of radiologists on the same task.
Materials And Methods:
For the comparison, a total of 105 cases of pulmonary fibrosis were studied (54 cases of nonspecific interstitial pneumonia and 51 cases of usual interstitial pneumonia). All diagnoses were interstitial lung disease board consensus diagnoses (radiologically or histologically proven cases) and were retrospectively selected from our database. Two subspecialized chest radiologists made a consensual ground truth radiological diagnosis, according to the Fleischner Society recommendations. A comparison analysis was performed between the INTACT system and 2 other radiologists with different years of experience (readers 1 and 2). The INTACT system consists of a sequential pipeline in which first the anatomical structures of the lung are segmented, then the various types of pathological lung tissue are identified and characterized, and this information is then fed to a random forest classifier able to recommend a radiological diagnosis.
Results:
Reader 1, reader 2, and INTACT achieved similar accuracy for classifying pulmonary fibrosis into the original 4 categories: 0.6, 0.54, and 0.56, respectively, with P > 0.45. The INTACT system achieved an F-score (harmonic mean for precision and recall) of 0.56, whereas the 2 readers, on average, achieved 0.57 (P = 0.991). For the pooled classification (2 groups, with and without the need for biopsy), reader 1, reader 2, and CAD had similar accuracies of 0.81, 0.70, and 0.81, respectively. The F-score was again similar for the CAD system and the radiologists. The CAD system and the average reader reached F-scores of 0.80 and 0.79 (P = 0.898).
Conclusions:
We found that a computer-aided detection algorithm based on machine learning was able to classify idiopathic pulmonary fibrosis with similar accuracy to a human reader.
Related Concept Videos
03:38Unilateral Lung Volume Analysis Using Micro-CT for Enhanced Assessment of Pulmonary Fibrosis in Preclinical Models
07:51Refined Murine Model of Idiopathic Pulmonary Fibrosis
06:03Oropharyngeal Administration of Bleomycin in the Murine Model of Pulmonary Fibrosis
04:48Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
10:26A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
07:51Hydra, a Computer-Based Platform for Aiding Clinicians in Cardiovascular Analysis and Diagnosis

