Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in
Sabong Srivannaboon1, Chareenun Chirapapaisan2
1Department of Ophthalmology, Faculty of Medicine Siriraj Hospital, Mahidol University, 2 Prannok Road, Bangkok, 10700, Thailand.
Purpose:
To compare the refractive outcomes following cataract surgery using conventional keratometry (K) and total keratometry (TK) for intraocular lens (IOL) calculation in the SRK/T, HofferQ, Haigis, and Holladay 1 and 2, as well as Barrett and Barrett TK Universal II formulas.
Methods:
Sixty eyes of 60 patients from Siriraj Hospital, Thailand, were prospectively enrolled in this comparative study. Eyes were assessed using a swept-source optical biometer (IOLMaster 700; Carl Zeiss Meditec, Jena, Germany). Posterior keratometry, K, TK, central corneal thickness, anterior chamber depth, lens thickness, axial length, and white-to-white corneal diameter were recorded. Emmetropic IOL power was calculated using K and TK in all formulas. Selected IOL power and predicted refractive outcomes were recorded. Postoperative manifest refraction was measured 3 months postoperatively. Mean absolute errors (MAEs), median absolute errors (MedAEs), and percentage of eyes within ± 0.25, ± 0.50, and ± 1.00 D of predicted refraction were calculated for all formulas in both groups.
Results:
Mean difference between K and TK was 0.03 D (44.56 ± 1.18 vs. 44.59 ± 1.22 D), showing excellent agreement (ICC = 0.99, all p < 0.001). Emmetropic IOL powers in all formulas for both groups were very similar, with a trend toward lower MAEs and MedAEs for TK when compared with K. The Barrett TK Universal II formula demonstrated the lowest MAEs. Proportion of eyes within ± 0.25, ± 0.50, and ± 1.00 D of predicted refraction were slightly higher in the TK group.
Conclusions:
Conventional K and TK for IOL calculation showed strong agreement with a trend toward better refractive outcomes using TK. The same IOL constant can be used for both K and TK.
Related Concept Videos
04:59Rotating the Intraocular Lens to Prevent Posterior Capsular Opacification in Cataract Surgeries
05:19Modeling Cataract Surgery in Mice
Reflection and Refraction
Light travels at different speeds depending on the material through which it is propagating. When light travels from one material to another, it will either slow down or speed up. In order to conserve energy and momentum, the light must change the direction in which it propagates. This bending of light is known as refraction. Some fraction of...
06:40An In Vivo Mouse Model of Total Intravenous Anesthesia During Cancer Resection Surgery
08:24The Joint Effect of Social Comparison and Social Distance on Evaluation of Intertemporal Choice Outcomes in Event-related Potential Studies
07:53Establishment of a Clinically Relevant Ex Vivo Mock Cataract Surgery Model for Investigating Epithelial Wound Repair in a Native Microenvironment

