Related Experiment Video
Updated: Jan 20, 2026

Endoscopic Cholesteatoma Surgery
Published on: January 19, 2022
Bilayer Graft for Incisionless In-Office Endoscopic Repair of Tympanic Membrane Perforations: A Pilot Study
Elliott D Kozin1,2, Daniel J Lee1,2, Aaron K Remenschneider1,2,3
1Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts, USA.
Abstract:
Tympanic membrane (TM) perforations may result in significant patient morbidity. While intraoperative myringoplasty or tympanoplasty allow for effective repair, not all patients are candidates for general anesthesia. Herein, we describe a novel graft design and technique for in-office repair of TM perforations in the clinic setting. Two pieces of porcine submucosa material were interdigitated to create a bilayer design with lateral and medial flanges. Topical and injected lidocaine were used for local anesthesia. The perforation was rimmed. Grafts were grasped, and medial flanges were placed through the perforation, with lateral flanges resting on the TM surface. TM repair occurred in 5 awake patients with a mean age of 72 years. There were no complications. All perforations healed, with 1 case requiring a minor in-office revision. Audiometry was performed at 4 weeks. The preoperative air-bone gap (mean 0.25, 0.5, 1, 2, and 4 kHz) was 12.2 ± 4.1 dB, and postoperatively, it was 4.2 ± 2.4 dB (P = .001). Novel design of available graft material may allow for effective in-office TM repair.
More Related Videos
09:07Author Spotlight: Advancing Endoscopic Ossiculoplasty – Techniques, Innovations, and Practical Guidance for Clinical Integration
Published on: January 26, 2024
08:27A Nanobar-Supported Lipid Bilayer System for the Study of Membrane Curvature Sensing Proteins in vitro
Published on: November 30, 2022
Related Concept Videos
08:47Endoscopic Cholesteatoma Surgery
09:07Techniques of Endoscopic Ossiculoplasty
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
08:27A Nanobar-Supported Lipid Bilayer System for the Study of Membrane Curvature Sensing Proteins in vitro
07:33Tethered Bilayer Lipid Membranes to Monitor Heat Transfer between Gold Nanoparticles and Lipid Membranes
08:23Automated Lipid Bilayer Membrane Formation Using a Polydimethylsiloxane Thin Film