Gamma-irradiation-induced micro-structural variations in flame-retardant polyurethane foam using synchrotron X-ray

A K Agrawal1, B Singh1, Y S Kashyap1

  • 1Technical Physics Division, Bhabha Atomic Research Centre, Mumbai, India.

Related Concept Videos

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography08:51

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography

We used synchrotron X-ray tomography at the European Synchrotron Radiation Facility (ESRF) to non-invasively produce 3D tomographic datasets with a pixel-resolution of 0.7µm. Using volume rendering software, this allows the reconstruction of internal structures in their natural state without the artefacts produced by histological...
13.6K
Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography (Micro-CT) Imaging Method09:11

Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography (Micro-CT) Imaging Method

We present a protocol using high-resolution micro-computed tomography imaging to determine whether spaceflight induced damage on ocular structures. The protocol shows the micro-CT-derived measurement of ex vivo rodent ocular structures. We demonstrate the ability to assess ocular morphological changes following spaceflight using a non-destructive tridimensional technique to evaluate ocular...
6.1K
Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography09:00

Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography

The protocol describes procedures to acquire high-spatial resolution computed tomography (CT) images of a granular soil during triaxial compression, and to apply image processing techniques to these CT images to explore the grain-scale mechanical behavior of the soil under...
13.7K
PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator10:48

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator

In the past, small animal irradiation was usually performed without the ability to target a well-delineated tumor volume. The goal was to mimic the treatment of human glioblastoma in rats. Using a small animal irradiation platform, we performed MRI-guided 3D conformal irradiation with PET-based sub-volume boosting in a preclinical...
10.0K
Proper Positioning and Restraint of a Rat Hind Limb for Focused High Resolution Imaging of Bone Micro-architecture Using In Vivo Micro-computed Tomography04:24

Proper Positioning and Restraint of a Rat Hind Limb for Focused High Resolution Imaging of Bone Micro-architecture Using In Vivo Micro-computed Tomography

This paper instructs users of in vivo micro-computed tomography (µCT) scanners how to anesthetize, correctly position and restrain the hind limb of a rat for minimal movement during high-resolution imaging of the tibia. The result is high quality images that can be processed to accurately quantify bone...
10.3K
Laser Micro-Irradiation to Study DNA Recruitment During S Phase07:11

Laser Micro-Irradiation to Study DNA Recruitment During S Phase

This protocol describes a non-invasive method to efficiently identify S-phase cells for downstream microscopy studies, such as measuring DNA repair protein recruitment by laser...
4.8K