Related Experiment Video
Updated: Jan 20, 2026

Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
Multi-element determination in some foods and beverages using silica gel modified with 1-phenylthiosemicarbazide
Durali Mendil1, Ozgur Dogan Uluozlu1, Mustafa Tuzen1
1Chemistry Department, Tokat Gaziosmanpaşa University, Tokat, Turkey.
Abstract:
1-Phenylthiosemicarbazide bonded modified silica gel (PTC-SG) was synthesised and characterised by FTIR, SEM and elemental analysis for a novel separation/preconcentration of multiple elements based on solid phase extraction. The analytical parameters including pH of solutions, amounts of PTC-SG, flow rates of sample, eluent type and sample volume were optimised. The adsorption capacities of PTC-SG were found to be 7.9, 6.4, 6.3, 8.3, 7.2, 8.9 and 6.6 mg/g for Cu(II), Cd(II), Pb(II), Co(II), Cr(III), Ni(II) and Mn(II), respectively. The limit of detection (LOD) was calculated as 3x the standard deviation(s) of the reagent blank (k = 3, N = 21) and the LOD values were obtained to be 0.98 µg L-1 (Cu), 0.65 µg L-1 (Cd), 0.57 µg L-1 (Pb), 1.12 µg L-1 (Co), 1.82 µL-1 (Cr), 1.67 µg L-1 (Ni) and 0.55 µg L-1 (Mn). Certified reference materials were used to test the validation of the present method. The new solid phase extraction method was successfully applied to determination of the amount of multiple elements in food and beverage samples.
Related Concept Videos
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Testing For Genetically Modified Foods
Genetic modification of foods has been a controversial issue due to debated concerns over health and environmental safety. This experiment demonstrates technical understanding of how food DNA is genetically identified, allowing for educated decision making about the safety and potential dangers of using genetically modified organisms (GMOs) in food supplies.
Polymerase Chain Reaction (PCR) is used to amplify food DNA...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
08:04Preparation of Functional Silica Using a Bioinspired Method
11:29Modified Terminal Restriction Fragment Analysis for Quantifying Telomere Length Using In-gel Hybridization