Related Experiment Video
Updated: Jan 19, 2026

Implantation of Human-Sized Coronary Stents into Rat Abdominal Aorta Using a Trans-Femoral Access
Published on: November 19, 2020
Relationship Between Stent Diameter, Platelet Reactivity, and Thrombotic Events After Percutaneous Coronary Artery
Björn Redfors1, Shmuel Chen2, Philippe Généreux3
1Clinical Trials Center, Cardiovascular Research Foundation, New York, New York; Department of Cardiology, Sahlgrenska University Hospital, Gothenburg, Sweden; NewYork-Presbyterian Hospital/Columbia University Medical Center, New York, New York.
Abstract:
Small vessel diameter and residual platelet reactivity are independent predictors of thrombotic events after percutaneous coronary intervention (PCI). We sought to determine whether an interaction exists between residual platelet reactivity and stent diameter regarding the occurrence of stent thrombosis and other adverse events after PCI. We stratified patients in the prospective ADAPT-DES registry who underwent single-lesion PCI according to if they received a small diameter stent (SDS, defined as a stent with a diameter of 2.25 mm). Patients receiving an SDS were compared with patients receiving a stent ≥2.5 mm using Kaplan-Meier rates and multivariable Cox proportional hazards regression. We defined major adverse cardiac events (MACE) as the composite of cardiac death, myocardial infarction, and stent thrombosis (ST). Among 5,608 patients who underwent single-lesion PCI in ADAPT-DES, 222 (4.0%) patients received an SDS. Patients with an SDS were more likely than patients without an SDS to have 3-vessel disease but received, on average, fewer stents and were less likely to present with a thrombotic lesion. Receiving versus not receiving an SDS was associated with increased risk of ST (adjusted hazard ratio 4.35, 95% confidence interval 1.95 to 9.73, p <0.001) as well as MACE (adjusted hazard ratio 1.75, 95% confidence interval 1.11 to 2.75, p = 0.02). There was no statistical interaction between platelet reactivity and SDS regarding ST (p = 0.12) or MACE (p = 0.51). In conclusion, PCI with small drug-eluting stents is associated with a high risk of thrombotic events, including ST. Further studies should explore whether alternative treatment strategies are appropriate in small vessels.
More Related Videos
13:10Direct Re-implantation of Left Coronary Artery into the Aorta in Adults with Anomalous Origin of Left Coronary Artery from the Pulmonary Artery ALCAPA
Published on: April 24, 2017
04:30A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Related Concept Videos
05:04Implantation of Human-Sized Coronary Stents into Rat Abdominal Aorta Using a Trans-Femoral Access
13:10Direct Re-implantation of Left Coronary Artery into the Aorta in Adults with Anomalous Origin of Left Coronary Artery from the Pulmonary Artery (ALCAPA)
04:30A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
07:53Standardized Rat Coronary Ring Preparation and Real-Time Recording of Dynamic Tension Changes Along Vessel Diameter
05:47Modified Technique for Coronary Artery Ligation in Mice
09:46Imaging In-Stent Restenosis: An Inexpensive, Reliable, and Rapid Preclinical Model