Related Concept Videos

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis04:30

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis

A model of stent implantation in mouse carotid artery is described. Compared to other similar methods, this procedure is very rapid, simple and accessible, offering the possibility to study in a convenient way the vascular wall reaction to different drug-eluting stents and the molecular mechanisms of...
26.2K
Implantation of Human-Sized Coronary Stents into Rat Abdominal Aorta Using a Trans-Femoral Access05:04

Implantation of Human-Sized Coronary Stents into Rat Abdominal Aorta Using a Trans-Femoral Access

This protocol describes the implantation of human coronary stents into the abdominal aorta of rats with an apoE-/- background using a trans-femoral access. Compared with other animal models, murine models carry the advantages of high throughput, reproducibility, ease of handling and housing, and a broad availability of molecular...
4.8K
Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents06:55

Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents

In the protocol, we present a method to manufacture a small caliber stent-graft by sandwiching a balloon expandable stent between two electrospun nanofibrous polyurethane...
9.4K
4D Printed Bifurcated Stents with Kirigami-Inspired Structures06:52

4D Printed Bifurcated Stents with Kirigami-Inspired Structures

Using a 3D printer, a shape memory polymer filament is extruded to form a branched tubular structure. The structure is patterned and shaped such that it can contract into a compact form once folded and then return to its formed shape when...
8.5K
Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention11:01

Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention

Our goals were to design, manufacture and test ferromagnetic stents for endothelial cell capture. Ten stents were tested for fracture and 10 more stents were tested for retained magnetism. Finally, 10 stents were tested in-vitro and 8 more stents were implanted in 4 pigs to show cell capture and...
12.0K
Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation06:04

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation

An upper-extremity approach for secondary access during transfemoral transcatheter aortic valve implantation is associated with fewer secondary access site-related bleeding complications and reduces time to mobilization in patients requiring extended pacing. This protocol aims to provide an extensive overview of the upper-extremity approach and guide operators in adopting this methodology.
510