Related Experiment Video
Updated: Jan 19, 2026

Multiplexed Fluorescent Immunohistochemical Staining, Imaging, and Analysis in Histological Samples of Lymphoma
Published on: January 9, 2019
Multiplexed Immunohistochemical Consecutive Staining on Single Slide (MICSSS): Multiplexed Chromogenic IHC Assay for
Guray Akturk1, Robert Sweeney1, Romain Remark2
1Tisch Cancer Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Abstract:
Disease states and cellular compartments can display a remarkable amount of heterogeneity, and truly appreciating this heterogeneity requires the ability to detect and probe each subpopulation present. A myriad of recent single-cell assays has allowed for in-depth analysis of these diverse cellular populations; however, fully understanding the interplay between each cell type requires knowledge not only of their mere presence but also of their spatial organization and their relation one to the other. Immunohistochemistry allows for the visualization of cells and tissue; however, standard techniques only allow for the use of very few probes on a single specimen, not allowing for in-depth analysis of complex cellular heterogeneity. A number of multiplex imaging techniques, such as immunofluorescence and multiplex immunohistochemistry, have been proposed to allow probing more cellular markers at once; however, many of these techniques still have their limitations. The use of fluorescent markers has an inherent limitation to the number of probes that can be simultaneously used due to spectral overlap. Moreover, other proposed multiplex IHC methods are time-consuming and require expensive reagents. Still, many of the methods rely on frozen tissue, which deviates from standards in human pathological evaluation. Here, we describe a multiplex IHC technique, staining for consecutive markers on a single slide, which utilizes similar steps and similar reagents as standard IHC, thus making it possible for any lab with standard IHC capabilities to perform this useful procedure. This method has been validated and confirmed that consecutive markers can be stained without the risk of cross-reactivity between staining cycles. Furthermore, we have validated that this technique does not lead to decreased antigenicity of subsequent epitopes probed, nor does it lead to steric hindrance.
Related Concept Videos
07:52Multiplexed Fluorescent Immunohistochemical Staining, Imaging, and Analysis in Histological Samples of Lymphoma
05:16Multiplexed Fluorescent Immunohistochemical Staining of Four Endometrial Immune Cell Types in Recurrent Miscarriage
09:12High-Throughput Automated Multiplex Immunofluorescence Assays for Translational Research
06:32Multiplex Immunohistochemical Analysis of the Spatial Immune Cell Landscape of the Tumor Microenvironment
08:29Measurement of Four Uterine NK Cell Subtypes Using Multiplexed Fluorescent Immunohistochemical Staining in Women with Repeated Implantation Failure
08:18Multiplexed Barcoding Image Analysis for Immunoprofiling and Spatial Mapping Characterization in the Single-Cell Analysis of Paraffin Tissue Samples

