Online mobile C-arm calibration using inertial sensors: a preliminary study in order to achieve CBCT
Imane Lemammer1,2, Olivier Michel3, Hacheme Ayasso3
1GIPSA-Lab, Grenoble INP, CNRS, Univ. Grenoble Alpes, 38000, Grenoble, France. lemammer.imane@gmail.com.
Purpose:
Cone beam computed tomography (CBCT) became increasingly popular over the last years. It allows more accurate diagnosis and treatment planning with a lower effective radiation dose. However, volume reconstruction algorithms require a very precise knowledge of the imaging geometry. Due to mechanical instabilities, mobile C-arms are incompatible with existing tomography algorithms. Therefore, C-arm online calibration is essential in order to achieve an accurate volume reconstruction.
Methods:
We present an online calibration method for mobile C-arms. It is based on tracking the detector and the X-ray source of the C-arm using three-axis gyroscopes and accelerometers. It aims to be precise and noninvasive. The performance of the calibration algorithm is evaluated in regard to the precision of the sensors and to whether or not dynamic models are considered. In addition, we present an algorithm which propagate the errors from the positions and orientations estimates to the 2D projections on the detector plane. Thus, we can evaluate the impact of the estimation errors on the acquired images.
Results:
The experiments are conducted on an experimental C-arm. The reached accuracy is [Formula: see text] for orientation and [Formula: see text] for position. These errors propagate as an error of [Formula: see text] for the 2D projections on the detector plane.
Conclusions:
The proposed calibration algorithm achieves an accuracy comparable to the precision of existing calibration methods. The required angle accuracy by CBCT algorithms is reached. However, improvements are needed to achieve the required position precision. The in-plane translations of the X-ray source and the detector are the most crucial parameters to estimate in order to conduct CBCT on mobile C-arms.
Related Concept Videos
Real-time Flight Control: Embedded Sensor Calibration and Data Acquisition
Overview
Autopilot allows aircraft to be stabilized using data collected from onboard sensors that measure the aircraft’s orientation, angular velocity, and airspeed. These quantities can be adjusted by the autopilot so that the aircraft automatically follows a flight plan from launch (takeoff) through recovery (landing). Similar sensor data is collected to control all types of aircraft,...
07:25An Objective and Child-friendly Assessment of Arm Function by Using a 3-D Sensor
08:31The Calibration and Use of Capacitance Sensors to Monitor Stem Water Content in Trees
08:08Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis
07:29Online Explorative Study on the Learning Uses of Virtual Reality Among Early Adopters
09:44Methods to Test Visual Attention Online