CT-morphologic and CT-textural patterns of response in inoperable soft tissue sarcomas treated with pazopanib-a
Michael Esser1, Cristopher Kloth2, Wolfgang M Thaiss1
1Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany.
Objective:
To analyze patterns of response in soft tissue sarcomas exposed to pazopanib using CT-morphologic and textural features and their suitability for evaluating therapeutic response.
Methods:
Retrospective evaluation of CT response and texture patterns in 33 patients (23 female; mean age: 61.2 years, range, 30-85 years) with soft tissue sarcomas treated with pazopanib from October 2008 to July 2017. Response evaluation was based on modified (m)CHOI-criteria and RECISTv.1.1 and classified as partial response (PR), stable disease (SD), progressive disease (PD). The following CT-texture (CTTA)-parameters were calculated: mean, entropy and uniformity of intensity/average/skewness/entropy of co-occurrence matrix and contrast of neighboring-gray-level-dependence-matrix.
Results:
Following mCHOI-criteria, 12 patients achieved PR, 7 SD and 14 PD. As per RECISTv.1.1 9 patients obtained PR, 9 SD and 15 PD. Frequent patterns of response were tumor liquefaction and necrosis (n=4/33, 12.1% each). Further patterns included shrinkage and cavitation (n=2/33, 6.1% each). In responders, differences in mean heterogeneity (p=0.01), intensity (p=0.03), average (p=0.03) and entropy of skewness (p=0.01) were found at follow-up whereas in non-responders, CTTA-parameters did not change significantly. Baseline-CTTA-features differed between responders and non-responders in terms of uniformity of skewness (p=0.045). Baseline-CTTA-parameters did not correlate with any morphologic response pattern.
Conclusion:
Most frequent patterns of response to pazopanib were tumor liquefaction and necrosis. Single CT-textural features show strong association with the response to pazopanib-although limited in relation to specific response patterns.
Advances In Knowledge:
Tumor liquefication and necrosis are important patterns of response to pazopanib. CT-texture analysis has limited associations with specific response patterns.
More Related Videos
Related Concept Videos
07:55Establishment of a Primary Culture of Patient-derived Soft Tissue Sarcoma
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
07:15A Mouse Model of Incompletely Resected Soft Tissue Sarcoma for Testing (Neo)adjuvant Therapies
Imaging Studies for Cardiovascular System V: CT
Combined SPECT and CT Imaging to Visualize Cardiac Functionality
Here we will demonstrate the fundamentals of single-photon emission computed tomography/computed tomography (SPECT/CT) imaging using mice. The technique involves injecting a radionuclide into a mouse, imaging the animal after it is distributed throughout the body, and then reconstructing the produced images to create a volumetric dataset. This can...
Micro-CT Imaging of a Mouse Spinal Cord
It's a little-known fact that the discovery and (inadvertent) use of X-rays garnered the first ever Nobel Prize in Physics. The famous X-ray image of Dr. Röntgen's wife's hand from 1895 that sent shock waves through the scientific community looks like most modern day 2D medical X-ray images. Though it is not the newest technology,...