Related Experiment Video
Updated: Jan 19, 2026

Robotic Ablation of Atrial Fibrillation
Published on: May 29, 2015
A deep neural network for 12-lead electrocardiogram interpretation outperforms a conventional algorithm, and its
Stephen W Smith1, Jeremy Rapin2, Jia Li2
1Hennepin County Medical Center, Department of Emergency Medicine, University of Minnesota, United States of America.
Background:
Automated electrocardiogram (ECG) interpretations may be erroneous, and lead to erroneous overreads, including for atrial fibrillation (AF). We compared the accuracy of the first version of a new deep neural network 12-Lead ECG algorithm (Cardiologs®) to the conventional Veritas algorithm in interpretation of AF.
Methods:
24,123 consecutive 12-lead ECGs recorded over 6 months were interpreted by 1) the Veritas® algorithm, 2) physicians who overread Veritas® (Veritas® + physician), and 3) Cardiologs® algorithm. We randomly selected 500 out of 858 ECGs with a diagnosis of AF according to either algorithm, then compared the algorithms' interpretations, and Veritas® + physician, with expert interpretation. To assess sensitivity for AF, we analyzed a separate database of 1473 randomly selected ECGs interpreted by both algorithms and by blinded experts.
Results:
Among the 500 ECGs selected, 399 had a final classification of AF; 101 (20.2%) had ≥1 false positive automated interpretation. Accuracy of Cardiologs® (91.2%; CI: 82.4-94.4) was higher than Veritas® (80.2%; CI: 76.5-83.5) (p < 0.0001), and equal to Veritas® + physician (90.0%, CI:87.1-92.3) (p = 0.12). When Veritas® was incorrect, accuracy of Veritas® + physician was only 62% (CI 52-71); among those ECGs, Cardiologs® accuracy was 90% (CI: 82-94; p < 0.0001). The second database had 39 AF cases; sensitivity was 92% vs. 87% (p = 0.46) and specificity was 99.5% vs. 98.7% (p = 0.03) for Cardiologs® and Veritas® respectively.
Conclusion:
Cardiologs® 12-lead ECG algorithm improves the interpretation of atrial fibrillation.
Related Concept Videos
11:21Robotic Ablation of Atrial Fibrillation
05:12Transesophageal Atrial Burst Pacing for Atrial Fibrillation Induction in Rats
03:31End-To-End Deep Neural Network for Salient Object Detection in Complex Environments
08:05Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
08:56Sterile Pericarditis in Aachener Minipigs As a Model for Atrial Myopathy and Atrial Fibrillation
04:16Electrocardiogram Recordings in Anesthetized Mice using Lead II