A Study of 219Rn Outgassing and 211Pb Contamination from 223Ra In dry, Liquid, and Murine Tissue Samples
Stephen Adler1, Kwamena Baidoo2, Elaine Jagoda2
1Clinical Research Directorate, Frederick National Laboratory for Cancer Research sponsored by the National Cancer Institute, Frederick MD.
Introduction:
A study of Pb contamination caused by the outgassing of Rn from Ra in dry, liquid, and murine tissues samples has been made to help design proper handling procedures for Ra in preclinical biodistribution work.
Materials And Methods:
Pb activity levels were measured from Ra in dry, liquid, and tissue samples using aspiration and autoradiography techniques.
Results:
Using aspiration techniques on dry samples of Ra, an average Rn outgassing rate of 51% ± 21% was measured with one measurement reaching as high as 81%. 31% ± 4% Pb contamination was measured within a 4.3 cm radius of a dry Ra source placed inside a 10-cm-diameter petri dish where the lip of the petri dish contained the Rn dissemination. Without the containment of the petri dish, Rn can reach as far as 7.8 cm from the source with trace levels spreading further. Using aspiration techniques on liquid samples of Ra, outgassing rates of Rn were 0.9% ± 0.3%. The outgassing levels in harvested organs from a biodistribution were as high as 10.1% ± 0.4% for an intraperitoneally injected mouse and 0.204% ± 0.006% for an intravenously injected mouse. The outgassing of the intravenously injected mouse carcass was less than 0.1%.
Conclusion:
In dry form, the high levels of Rn outgassing from a Ra source necessitate the use of ventilated biohoods when handling or preparing dry Ra from source vials. The very low levels of Rn outgassing from Ra liquid sources reduces exposure to Rn by a factor of 50. Rn exposure from murine organ tissue reaches levels of 10% when handling organs from an intraperitoneal injection and less than 0.2% for an intravenous injection.
Related Concept Videos
08:32Measurement of Outgassing Rates of Steels
06:04Source and Route of Pyrrolizidine Alkaloid Contamination in Tea Samples
05:12Murine Nasal Lavage Fluid Collection without Blood Contamination
13:16Assessment of DNA Contamination in RNA Samples Based on Ribosomal DNA
05:33Using Robotic Systems to Process and Embed Colonic Murine Samples for Histological Analyses
07:20Dried Blood Spot Collection of Health Biomarkers to Maximize Participation in Population Studies