Related Concept Videos

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities06:51

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities

This document describes a new dosimetry protocol for cell irradiations using low energy X-ray equipment. Measurements are performed in conditions simulating real cell irradiation conditions as much as...
5.5K
Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy11:38

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy

The current priority in breast cancer radiotherapy is to reduce cardiac doses without compromising target tissue coverage. The voluntary breath-hold technique described here is a simple, inexpensive solution to this problem and capable of being instituted widely without the need for specialized...
47.4K
A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods09:49

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods

This method estimates the absorbed dose of different structures for peptide-receptor-radionuclide-therapy (PRRT) with the possibility of avoiding organ overlap on 2D-projections. Serial whole-body planar images permit estimation of mean absorbed doses along the whole body, while the hybrid approach, combining planar images and 3D-SPECT/CT image, overcomes the limitations of structure...
10.4K
Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy08:54

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy

Stereotactic body radiotherapy (SBRT) requires rigorous accuracy and precision for delivering high radiation doses per fraction to small treatment volumes to improve tumor control and simultaneously reduce toxicity. Herein, we present a noninvasive and clinically convenient respiratory motion management protocol for SBRT for liver metastases.
14.9K
Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator07:31

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

A growing number of radiation therapy devices offer the advantage of delivering the dose through very small beams to the tumor, allowing for increased conformity and higher doses per fraction. Many different detectors can be used for the dosimetry of these small fields. In the present study, the effect of ion recombination is investigated for a liquid ionization chamber using a stereotactic radiation therapy...
12.2K
Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System08:25

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System

Radiation therapy is a highly complex cancer treatment that requires multiple specialists to create a treatment plan and provide quality assurance (QA) prior to delivery to a patient. This protocol describes the use of a fully automated system, the Radiation Planning Assistant (RPA), to create high-quality radiation treatment...
15.9K