Exact diagonal representation of normal mode energy, occupation number, and heat current for phonon-dominated thermal

Anant Raj1, Jacob Eapen1

  • 1Department of Nuclear Engineering, North Carolina State University, Raleigh, North Carolina 27695, USA.

Related Concept Videos

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy10:40

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy

The manuscript describes a method of phonon-assisted quasi-resonant fluorescence spectroscopy that incorporates both laser-limited resolution and photoluminescence (PL) spectroscopy. This method utilizes optical phonons to provide linewidth-limited resolution spectra of atom-like semiconductor structures in the energy domain. The method is also easily realized with a single spectrometer optical spectroscopy setup.
7.9K
Characterization of Thermal Transport in One-dimensional Solid Materials05:20

Characterization of Thermal Transport in One-dimensional Solid Materials

The TET (transient electro-thermal) technique is an effective approach developed to measure the thermal diffusivity of solid...
19.5K
Thermal Limits Determination for Zooplankton Using a Heat Block07:16

Thermal Limits Determination for Zooplankton Using a Heat Block

The present protocol illustrates the use of commercially available components to generate a stable and linear thermal gradient. Such gradient can then be used to determine the upper thermal limit of planktonic organisms, particularly invertebrate larvae.
1.7K
Quantifying Heat02:46

Quantifying Heat

Thermal Energy Microscopically, thermal energy is the kinetic energy associated with the random motion of atoms and molecules. Temperature is a quantitative measure of “hot” or “cold”, which depends on the amount of thermal energy. When the atoms and molecules in an object are moving or vibrating quickly, they have a higher average kinetic energy (KE) (or higher thermal energy), and the object is perceived as “hot”, or it is described as being at a higher temperature. When the...
61.7K
Evaluating Plasmonic Transport in Current-carrying Silver Nanowires09:00

Evaluating Plasmonic Transport in Current-carrying Silver Nanowires

Silver nanowires can simultaneously transport electrons and optical information in the form of surface plasmons. A procedure is described here to realize such a shared circuitry and the limitations at propagating both information carriers are...
5.6K
Fisher's Exact Test01:08

Fisher's Exact Test

Fisher's exact test is a statistical significance test widely used to analyze 2x2 contingency tables, particularly in situations where sample sizes are small. Unlike the chi-squared test, which approximates P-values and assumes minimum expected frequencies of at least five in each cell, Fisher's exact test calculates the exact probability (P-value) of observing the data or more extreme results under the null hypothesis. This feature makes it especially valuable when the assumptions of...
1.2K