Related Experiment Video
Updated: Jan 19, 2026

Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
The impact of percutaneous coronary intervention using the novel dynamic coronary roadmap system
Takayuki Yabe1,2, Toshiya Muramatsu3, Reiko Tsukahara3
1Department of Cardiovascular Medicine, Toho University Faculty of Medicine, 6-11-1 Omorinishi, Ota-ku, Tokyo, 143-8541, Japan. takayuki.yabe@med.toho-u.ac.jp.
Abstract:
The dynamic coronary roadmap (DCR) is a novel technology that creates a dynamic, motion-compensated, real-time overlay of the coronary arteries on a fluoroscopic image. Whether the DCR reduces contrast volume and enables safe and effective treatment was examined. A total of 146 patients undergoing percutaneous coronary intervention (PCI) from June 2017 to September 2017 in our hospital were retrospectively evaluated. Chronic total occlusion lesions, acute coronary syndrome, and hemodialysis patients were excluded. Patients were divided into the control group (PCI without DCR, 92 patients, 103 lesions) and the DCR group (38 patients, 43 lesions). The primary endpoint was contrast medium volume, and secondary endpoints were radiation dose, fluoroscopy time, and clinical success rate. There was no significant difference in the success rate (100% vs. 100%, P = 1.000) between the groups. Fluoroscopy time (16.3 ± 11.2 min. vs. 11.4 ± 5.5 min, P = 0.007) and contrast medium volume (152.1 ± 73.0 ml vs. 118.8 ± 49.7 ml, P = 0.006) were significantly lower in the DCR group than in the control group. DCR use during PCI was associated with a significant reduction in contrast volume and fluoroscopy time compared to a control group despite similar clinical, lesion, and procedural characteristics.
More Related Videos
06:39Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Related Concept Videos
10:28Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
06:39Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
10:03Coronary Progenitor Cells and Soluble Biomarkers in Cardiovascular Prognosis after Coronary Angioplasty
05:07Dynamic Assessments of Coronary Flow Reserve after Myocardial Ischemia Reperfusion in Mice
06:25Coronary Angiography During Ex-Situ Heart Perfusion in a Porcine Model