Related Experiment Video
Updated: Jan 19, 2026

Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow
Published on: April 29, 2011
Effect of Viscoelasticity on Arterial-Like Pulsatile Flow Dynamics and Energy
Winston Elliott1, Dongjie Guo2, Gruschen Veldtman3
1Department of Mechanical Engineering, University of Colorado at Boulder, 1111 Engineering Drive, ECME 114, Boulder, CO 80309.
Abstract:
Time-dependent arterial wall property is an important but difficult topic in vascular mechanics. Hysteresis, which appears during the measurement of arterial pressure-diameter relationship through a cardiac cycle, has been used to indicate time-dependent mechanics of arteries. However, the cause-effect relationship between viscoelastic (VE) properties of the arterial wall and hemodynamics, particularly the viscous contribution to hemodynamics, remains challenging. Herein, we show direct comparisons between elastic (E) (loss/storage < 0.1) and highly viscoelastic (loss/storage > 0.45) conduit structures with arterial-like compliance, in terms of their capability of altering pulsatile flow, wall shear, and energy level. Conduits were made from varying ratio of vinyl- and methyl-terminated poly(dimethylsiloxane) and were fit in a mimetic circulatory system measuring volumetric flow, pressure, and strain. Results indicated that when compared to elastic conduits, viscoelastic conduits attenuated lumen distension waveforms, producing an average of 11% greater cross-sectional area throughout a mimetic cardiac cycle. In response to such changes in lumen diameter strain, pressure and volumetric flow waves in viscoelastic conduits decreased by 3.9% and 6%, respectively, in the peak-to-peak amplitude. Importantly, the pulsatile waveforms for both diameter strain and volumetric flow demonstrated greater temporal alignment in viscoelastic conduits due to pulsation attenuation, resulting in 25% decrease in the oscillation of wall shear stress (WSS). We hope these findings may be used to further examine time-dependent arterial properties in disease prognosis and progression, as well as their use in vascular graft design.
Related Concept Videos
10:02Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow
Energy Dynamics
Energy is one of the most important abiotic factors in an ecosystem and organisms in an ecosystem are connected by the flow of energy and matter among one another. Since energy can be neither created nor destroyed, it can only change form or be transferred to the next organism in a food chain. For example, every time a cow grazes on grass or an osprey hunts and consumes fish, energy is transferred from the consumed organism to the consumer. Each of these interactions in a food...
Energy Dynamics
ExpandNOTE: In this lab you will grow caterpillars in conditions with and without food to examine the transfer of biomass in a typical trophic system.
Weigh and record the wet mass of enough leaves of cabbage to line the bottom of a plastic tub.
Then, collect two batches of five caterpillars from their cabbage habitat, and weigh and record the wet mass of each batch separately in individual weigh boats. Make sure to tare the balance before each measurement....
Energy Dynamics
ExpandTo obtain the percent biomass of a representative cabbage before the experiment, use a paper towel to wash and pat dry the inner leaves of a grocery store cabbage.
Place the cabbage into a pre-weighed Petri dish on a balance to determine the wet mass of the vegetable, and then transfer the cabbage and the dish into a 37 °C incubator for 48 hours.
At the end of the incubation, weigh cabbage in the dish again to obtain the dry mass of the cabbage.
Then, calculate...
08:08Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
11:22Engineering Biological-Based Vascular Grafts Using a Pulsatile Bioreactor