Related Experiment Video
Updated: Jan 19, 2026
Operation of High-Performance Liquid Chromatography HPLC
Published on: April 30, 2023
Quick Test for Determination of N-Bombs (Phenethylamine Derivatives, NBOMe) Using High-Performance Liquid
Hadil M Elbardisy1,2, Christopher W Foster1, Jack Marron1,1
1Faculty of Science and Engineering and MANchester DRug Analysis and Knowledge Exchange (MANDRAKE), Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, U.K.
Abstract:
The emergence of a new class of novel psychoactive substances, N-benzyl-substituted phenethylamine derivatives so-called "NBOMes" or "Smiles", in the recreational drug market has forced the development of new sensitive analytical methodologies for their detection and quantitation. NBOMes' hallucinogenic effects mimic those of the illegal psychedelic drug lysergic acid diethylamide (LSD) and are typically sold as LSD on blotter papers, resulting in a remarkable number of fatalities worldwide. In this article, four halide derivatives of NBOMe, namely, 2-(4-fluoro-2,5-dimethoxyphenyl)-N-(2-methoxybenzyl)ethan-1-amine, 2-(4-chloro-2,5-dimethoxyphenyl)-N-(2-methoxybenzyl)ethan-1-amine, 2-(4-bromo-2,5-dimethoxyphenyl)-N-(2-methoxybenzyl)ethan-1-amine, and 2-(4-iodo-2,5-dimethoxyphenyl)-N-(2-methoxybenzyl)ethan-1-amine, were detected and quantified simultaneously using a high-performance liquid chromatographic method, and two detection systems were compared: photodiode array detection (detection system I) and amperometric detection via a commercially available impinging jet flow-cell system incorporating embedded graphite screen-printed macroelectrodes (detection system II). Under optimized experimental conditions, linear calibration plots were obtained in the concentration range of 10-300 and 20-300 μg mL-1, for detection systems I and II, respectively. Detection limit (limit of detection) values were between 4.6-6.7 and 9.7-18 μg mL-1, for detection systems I and II, respectively. Both detectors were employed for the analysis of the four NBOMe derivatives in the bulk form, in the presence of LSD and adulterants commonly found in street samples (e.g. paracetamol, caffeine, and benzocaine). Furthermore, the method was applied for the analysis of simulated blotter papers, and the obtained percentage recoveries were satisfactory, emphasizing its advantageous applicability for the routine analysis of NBOMes in forensic laboratories.
Related Concept Videos
High-Performance Liquid Chromatography (HPLC)
High-performance liquid chromatography (HPLC) is an important analytical method commonly used to separate and quantify components of liquid samples. In this technique, a solution (first phase) is pumped through a column that contains a packing of small porous particles with a second phase bound to the surface. The different solubilities of the sample components in the two phases cause the components to move through the column with different average...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors

