Pinwheel-Shaped Titanium Plates Should Be Fixed to the Skull Using All Screw Holes to Protect the Plates from Being
Shoko Merrit Yamada1, Katsuya Gorai2, Koichi Gonda2
1Department of Neurosurgery, Teikyo University Mizonokuchi Hospital, 5-1-1 Futago, Takatsu-ku, Kawasaki, Kanagawa 213-8507, Japan.
Introduction:
In cranioplasty, pinwheel-shaped titanium mini plates are frequently used to cover bone defects produced by burr holes, and it is common to insert screws through only a few of the holes in cranial flap fixation.
Presentation Of Case:
A 69-year-old man who had undergone clipping surgery for subarachnoid hemorrhage 16 years previously visited our clinic because a titanium plate had penetrated his scalp one month after he was hit on the head by a wall cabinet. Imaging studies revealed that part of the titanium plate had bent outwards and penetrated the skin. The plate was surgically removed, a relief skin incision was made 6 cm posterior to the skin defect to suture the defected portion without causing tension, and a skin graft was applied to the relief skin incision portion. Two months after the maneuver, the skin graft had been successfully incorporated without infection.
Discussion:
Even after the subcutaneous and the cutaneous tissue have completely covered the pinwheel-shaped titanium mini plate, an edge without screw fixation can be easily bent by a hard blow to the overlying scalp. We recommend fixation of pinwheel-shaped titanium plates used in cranioplasty through all screw holes to protect against the plate being bent.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
06:27Improved Fecundity and Fertility Assay for Aedes aegypti using 24 Well Tissue Culture Plates EAgaL Plates
Published on: May 4, 2021
Related Concept Videos
05:45Stabilizing a Femur Osteotomy with a Plate Fixation in Ambystoma mexicanum
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Serial Dilutions and Plating: Microbial Enumeration
1 Department of Biological Sciences, Wagner College, 1 Campus Road, Staten Island NY, 10301
Quantitative assessment of prokaryotes can be onerous given their abundance, propensity for exponential proliferation, species diversity within a population, and specific physiological needs. Compounding this challenge, is the four-phase nature in which bacteria replicate (lag, log, stationary and death). The ability to accurately...
06:27Improved Fecundity and Fertility Assay for Aedes aegypti using 24 Well Tissue Culture Plates (EAgaL Plates)
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
07:28Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor