Kidney Failure After Occlusion of Accessory Renal Arteries in Endovascular Abdominal Aneurysm Repair
K Maurer1, N Verloh2, L Lürken2
1Department of Radiology, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany. Katharina.Maurer@stud.uni-regensburg.de.
Purpose:
To evaluate the incidence of acute renal failure and chronic kidney disease due to occlusion of accessory renal arteries during endovascular aneurysm repair of infrarenal abdominal aortic aneurysm.
Material And Methods:
We retrospectively reviewed the course of 181 patients (mean age, 71, SD ± 9 years) who underwent EVAR of infrarenal abdominal aortic aneurysm. The renal vessel anatomy was analyzed in all pre- and postoperative CT scans. Diameter and origin of accessory renal arteries were evaluated. Renal function was determined by pre- and postoperative serum creatinine and eGFR levels. Long-term follow-up (>3 months) of patients was available in 121 cases (66.9%). Acute kidney injury and chronic kidney failure were defined according to guidelines of "Kidney Disease: Improving Global Outcomes" (KDIGO).
Results:
In 65 of 181 patients (33.9%), 82 accessory renal arteries were identified preoperatively. In 19 of 181 patients (10.5%), one or more accessory renal arteries were covered and subsequently occluded by the implanted stent-graft device. Neither acute kidney injury (10.3% vs 12.5%; p = .785) nor chronic kidney disease (10.7% vs 15.38%; p = .452) was detected significantly more often in patients with covered accessory renal artery. The only significant predictor of acute kidney injury was the preoperative serum creatinine level (1.12 mg/dl vs. 0.98 mg/dl; p = .03). Significant predictors for chronic kidney disease were preoperative serum creatinine, eGFR, and impaired renal function (p < .001).
Conclusion:
Coverage of accessory renal artery due to stent-graft does not lead either to temporary acute kidney injury after endovascular aneurysm repair or to chronic kidney disease.
Level Of Evidence:
Level II b.
Related Concept Videos
08:51A New Murine Model of Endovascular Aortic Aneurysm Repair
09:02A Large Animal Model for Acute Kidney Injury by Temporary Bilateral Renal Artery Occlusion
11:18Direct Drug Delivery to Kidney via the Renal Artery
07:54Use of a Hanging-weight System for Isolated Renal Artery Occlusion
07:21Microsurgical Creation of Giant Bifurcation Aneurysms in Rabbits for the Evaluation of Endovascular Devices
11:13Porcine Model of Infrarenal Abdominal Aortic Aneurysm