Sensitive Detection of Gas-Phase Glyoxal by Electron Attachment Reaction Ionization Mass Spectrometry
Xue-Wei Lu1,2,3, Li-Xue Jiang1,2,3, Jingwei Liu4
1State Key Laboratory for Structural Chemistry of Unstable and Stable Species , Institute of Chemistry, Chinese Academy of Sciences , Beijing 100190 , P. R. China.
Abstract:
Glyoxal (GLY) acts as a key contributor to tropospheric ozone production and secondary organic aerosol (SOA) formation on local to regional scales. The detection of GLY provides useful indicators of fast photochemistry occurring in the lower troposphere. The fast and sensitive detection of GLY is thus important, while traditional chemical ionization such as the proton-transfer reaction (PTR) is extremely limited by the poor detection limit and extensive fragmentation. To address these limitations, electron attachment reaction (EAR) ionization was applied to detect GLY. The generation of parent anions (GLY-) without fragmentation was observed, and cryogenic photoelectron imaging spectroscopy further characterized the structure of GLY-. The detection limit was estimated to be as low as (52 ± 1) pptv (parts per trillion by volume) with 1 min measurements. Other components in ambient air, such as water, carbon dioxide, and trace gases (acetone, propanal, etc.) have no effect on the detection of GLY. The EAR ionization is more promising than PTR ionization in detecting GLY. The detection of GLY in ambient air by the EAR ionization has been demonstrated.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...