Abstract:
The radiotracer's residence time distribution (RTD) is an important study of the performance of industrial process reactors.The application of radiotracers is the method used to diagnose the functioning of packed distillation columns. This paper presents the results of an experiment carried out using the Technitium-99 (Mo99) radiotracer to determine the RTD in a laboratory-scale packed distillation column.The concentration of the radiotracer is monitored using eight scintillation detectors.The obtained data is treated for background correction, radioactive decay correction, starting point correction, filtering, and data extrapolation. After this preprocessing, two mathematical models are investigated on this data using International Atomic Energy Agency (IAEA) RTD software. The parameters of each model are optimized in oder to calculate the value of the RTD, and to determine the model which gives the best match with the experimental data. The appropriate model is than selected. Consequenly the one with the best match, is used to deduce the crucial parameter RTD in this experiment.
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Principles Of Column Chromatography
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Fast Reactions
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...