Dose-optimized computed tomography of the cervical spine in patients with shoulder pull-down: Is image quality
Magdalini Tozakidou1, Schu-Ren Yang2, Balazs K Kovacs2
1Clinic of Radiology and Nuclear Medicine, University of Basel Hospital, University of Basel, Switzerland; Department of Radiology and Nuclear Medicine, Devision of Pediatric Radiology, University Hospital Eppendorf, Hamburg, Germany.
Purpose:
Superimposing soft tissue and bony structures in computed tomography (CT) of the cervical spine (C-spine) is a limiting factor in optimizing radiation exposure maintaining an acceptable image quality. Therefore, we assessed image quality of dose-optimized (DO) C-spine CT in patients capable of shoulder pull-down in an emergency setting.
Methods And Materials:
DO-CT (105mAs/120 kVp) of the C-spine in trauma settings was performed in patients with shoulder pull-down if C5 was not superimposed by soft tissue on the lateral topogram, otherwise standard-dose (SD)-CT (195 mAs/120 kVp) was performed. 34 DO (mean age, 68y ± 21; BMI, 24.2 kg/m2 ± 3.2) and 34 SD (mean age 70y ± 19; BMI 25.7 kg/m2 ± 4.4) iterative reconstructed CTs were evaluated at C2/3 and C6/7 by two musculoskeletal radiologists. Qualitative image noise and morphological characteristics of bony structures (cortex, trabeculae) were assessed on a Likert scale. Quantitative image noise was measured and effective dose (ED) was recorded. Parameters were compared using Mann-Whitney-U-test (p < 0.05).
Results:
At C2/3, DO-CT vs. SD-CT yielded comparable qualitative noise (mean, 1.3 vs. 1.0; p = 0.18) and morphological characteristics, but higher quantitative noise (27.2 ± 8.8HU vs. 19.6 ± 4.5HU; p < 0.001). At C6/7, DO-CT yielded lower subjective noise (1.9; SD-CT 2.2; p = 0.017) and better morphological characteristics with higher visibility scores for cortex (p = 0.001) and trabeculae (p = 0.03). Quantitative noise did not differ (p = 0.24). Radiation dose was 51% lower using DO-CT (EDDO-CT 0.80 ± 0.1 mSv; EDSD-CT 1.63 ± 0.2 mSv; p < 0.001).
Conclusion:
C-spine CT with dose reduction of 51% showed no image quality impairment. Additional pull-down of both shoulders allowed better image quality at lower C-spine segments as compared to a standard protocol.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...