Related Experiment Video
Updated: Jan 19, 2026

Endotracheal Intubation of Rabbits Using a Polypropylene Guide Catheter
Published on: November 13, 2017
Ambu AuraGain versus intubating laryngeal tube suction as a conduit for endotracheal intubation
Melanio A Bruceta1, Dalal G Priti1, Paul McAllister2
1Department of Anesthesiology and Perioperative Medicine, Penn State Health Milton S. Hershey Medical Center and College of Medicine, Hershey, PA 17033, USA.
Background And Aims:
Newly developed supraglottic airway devices (SGAs) are designed to be used both for ventilation and as conduits for endotracheal intubation with standard endotracheal tubes (ETTs). We compared the efficacy of the Ambu AuraGain (AAG) and the newly developed intubating laryngeal tube suction disposable (ILTS-D) as conduits for blind and fiber-optically guided endotracheal intubation in an airway mannequin.
Material And Methods:
This is a prospective, randomized, crossover study in an airway mannequin, with two arms: blind ETT insertion by medical students and fiber-optically guided ETT insertion by anesthesiologists. The primary outcome variable was the time to achieve an effective airway through an ETT using AAG and ILTS-D as conduits. Secondary outcome variables were the time to achieve effective supraglottic ventilation and successful exchange with an ETT, and the success rates for blind endotracheal intubation and fiber-optically guided intubation techniques for both SGAs.
Results:
Forty participants were recruited to each group. All participants were able to insert both devices successfully on the first attempt. For blind intubation, the success rate for establishing a definitive airway with an ETT using the SGA as a conduit was significantly higher with ILTS-D (82.5%) compared with AAG (20.0%) (P < 0.001). None of the participants were able to successfully complete the exchange of the SGA for the ETT with the AAG. In the fiber optic guided intubation group, the rate of successful exchange was significantly higher with ILTS-D (84.6%) compared with AAG (61.5%) (P = 0.041).
Conclusion:
The ILTS-D successfully performs in an airway mannequin with higher success rate and shorter time for blindly establishing an airway with an ETT using the SGA as a conduit, compared with AAG. Further clinical trials are warranted.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Suctioning II: Procedure