Related Experiment Video
Updated: Jan 19, 2026

Calvarial Model of Bone Augmentation in Rabbit for Assessment of Bone Growth and Neovascularization in Bone Substitution Materials
Published on: August 13, 2019
Comparison of microsurgical and macrosurgical technique using bioactive synthetic bone graft and collagen membrane
Deepali Jain1, Ranjana Mohan1, Vikram Deep Singh1
1Department of Periodontology, Teerthanker Mahaveer Dental College and Research Centre, Moradabad, Uttar Pradesh, India.
Background:
Implant site development can be effective in minimizing postextraction alveolar ridge resorption in the esthetic region. Microsurgical approach has demonstrated substantial improvement in soft-tissue architecture.
Aim And Objectives:
The aim of the present study was to evaluate and compare the efficacy of microsurgical technique with conventional one for implant site development utilizing biphasic hydroxyapatite/beta-tricalcium phosphate bone graft substitute and collagen membrane.
Materials And Methods:
Thirty extraction sites were planned for implant placement and randomly divided into control (macrosurgical/conventional) and test (microsurgery) sites. Clinical measurements were recorded at four different points of extraction socket, i.e., mesiobuccal, midbuccal, distobuccal, and midlingual/palatal at baseline, 3, 6, and 9 months. Postoperative neovascularization at control and test site was evaluated by ultrasound Doppler flowmetry at baseline, 10th day, and 1 month. Radiological assessment of bone density (Hounsfield units) was measured at control and test sites at baseline, 6 and 9 months by computed tomography. Data was subjected to statistical analysis.
Results:
Significant socket fill at all the four different sites was observed and found to be statistically significant at test as compared to control group with better tissue contour after 3, 6, and 9 months. Test group demonstrated better neovascularization (P < 0.05) with significantly higher bone density (P = 0.000) at different time intervals.
Conclusions:
The results indicate that the augmentation of extraction sockets, not only improved the quality of bone in both the techniques but the utilization of microsurgical instruments and microsutures under magnification definitely enhanced the quality of soft tissues which is imperative for successful implant placement and its survival.