Do bevacizumab solutions interact with silicone or polyurethane catheters during an infusion through implantable

Nicolas Tokhadzé1, Philip Chennell1, Régis Cueff2

  • 1Universite Clermont Auvergne, CHU Clermont Ferrand, CNRS, Sigma Clermont, ICCF, 63000 Clermont-Ferrand, France.

This work aims to evaluate the possible impact of interactions between bevacizumab solutions and an implantable port equipped with a silicone or a polyurethane catheter after infusion through a complete infusion set-up in simulated use conditions. Physico-chemical and structural stability of bevacizumab solution was assessed by visual examination, subvisible particles counting, dynamic light scattering, size exclusion chromatography and ion exchange chromatography. Mechanical properties of the catheters were evaluated by measuring Shore A hardness, strain at break, strain at stress and Young's modulus. The physico-chemical surface state of the catheters was assessed by FTIR-ATR spectroscopy, scanning electron microscopy (SEM) and by water contact angle measurement. The analysis of the bevacizumab solution did not highlight any signs of instability or loss of active substance. Mechanical properties of both materials remained unchanged after the infusion. During material analysis, a decrease in water contact angle observed after infusion and was more pronounced for polyurethane catheters than for silicone, possibly due to bevacizumab adsorption or possible leachable extraction from the materials. Surface modifications were also noted at SEM. This study did not highlight any modifications that could alter the quality of the bevacizumab infusion, nor of the infusion catheter in polyurethane or silicone, despite a modification of surface hydrophilicity. Even if after a single infusion, implantable ports remained safe to use, they aim to be used for several infusion of various drugs during their lifetime, and further studies are needed to assess the impact of repeated infusions.

Related Concept Videos

Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
1.4K
Cardiac Catheterization IV: Nursing Management01:26

Cardiac Catheterization IV: Nursing Management

Nursing responsibilities before cardiac catheterization include:Assess for allergies and establish baseline health status.Before cardiac catheterization, assess the patient for allergies to contrast dye. Perform a comprehensive baseline assessment, including vital signs, heart and breath sounds, and a neurovascular assessment of the extremities, noting distal pulses, skin color, and temperature. Instruct the patient to fast for 8-12 hours before the procedure. Evaluate baseline laboratory...
661
Venous Thrombosis III: Interprofessional Care01:29

Venous Thrombosis III: Interprofessional Care

Venous thrombosis requires effective prevention and treatment strategies to improve patient outcomes and reduce potential complications.Prevention StrategiesHealthcare providers must prioritize preventing venous thromboembolism (VTE) for all adult patients upon admission. Interventions depend on bleeding and thrombosis risk, medical history, current medications, diagnoses, planned procedures, and patient preferences. Patients on bed rest should change positions every two hours and, if not...
281